Commissioning
Alcatel Vacuum Technology France - ACT 250 addendum
18
January 2001
Detailed description of RS commands
HDR
Syntax
Result
IDN
Syntax
Result
Identies the device which is communicating, and its
software version
#adrIDN<CR>[<LF>]
#adr, VS.... - Vx.zz
or
#adr, VS.... - Vx.zz for Alcatel pump type
Returns the type of Variator Supervisor, the software version (x), the
software edition (zz), and the type of pump for which this variator is
set up.
Denes the start character for a command reply string
#adrHDRnnn<CR>[<LF>]
nnn: 3-digit decimal value of the ascii code of the
corresponding character (with leading zeros).
condition : 020 nnn 255
?adr,ok ? is the desired character.
#adr,ErrX if error
Allows the user to distinguish between the rst character in a command string
(for which # cannot be changed) and the rst character of a reply string.
Affects the rst character of all replies.
Default value: the hash sign, # (ascii code = 035)
If ok, the selected value is automatically stored in user memory.
ECH
Syntax
Result
Enables or disables command echoing
#adrECHON<CR>[<LF>]
enables all characters received to be echoed over the serial port
or
#adrECHOFF<CR>[<LF>]
disables characters received from being echoed over the serial port.
#adr,ok
Comments:
- This command is disabled in RS 485 operation, the value OFF
is required.
- Using a loop-type RS 232 network requires ECHON.