Detailed description of RS commands
LEV
Syntax
Result
LNG
Syntax
Result
See also: SHT
Returns the state of the parameters dened by SET
#adrLEV<CR>[<LF>]
#adr,nnnnn,sssss,aaaa,hhhhh or
#adr,nnnnn rpm,sssss rpm,aaaa mA,hhhhh hours
Returns the current values:
nnnnn : speed set point
sssss : stand-by speed
aaaa : max. current set point
hhhhh : alert level for pump bearing maintenance
Returns the strings sent with the identication sub-strings
#adrLNG<CR>[<LF>]
#adr,ok
AVT>
Allows the parameters returned by the DLR, LEV and SPD commands
to be identied with sub-strings. DLR, LEV, SPD.
Also generates the AVT> prompt each time a <CR> character is
received.
NSP
Syntax
Result
See also: RPM, SBY
Switches the speed set point to the nominal speed value
#adrNSP<CR>[<LF>]
#adr,ok
The speed set point for the pump is set to its nominal value.
This conguration is automatically saved in user memory.