Chicago Electric 38941 Saw User Manual


 
Page 7SKU 38941
For technical questions, please call 1-800-444-3353.
8. Protect your extension cords from sharp objects, excessive heat, and damp or wet ar-
eas.
RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS*
(120 OR 240 VOLT)
NAMEPLATE
AMPERES
(at full load)
EXTENSION CORD LENGTH
25 Feet 50 Feet 75 Feet 100 Feet 150 Feet
0 – 2.0 18 18 18 18 16
2.1 – 3.4 18 18 18 16 14
3.5 – 5.0 18 18 16 14 12
5.1 – 7.0 18 16 14 12 12
7.1 – 12.0 18 14 12 10 -
12.1 – 16.0 14 12 10 - -
16.1 – 20.0 12 10 - - -
TABLE A
* Based on limiting the line voltage drop to ve volts at 150% of the rated amperes.
SYMBOLOGY
Double Insulated
Canadian Standards Association
Underwriters Laboratories, Inc.
V~
Volts Alternating Current
A
Amperes
n
0
xxxx/min.
No Load Revolutions per Minute (RPM)
Note: Performance of this tool may vary depending on variations in local line voltage. Extension
cord usage may also affect tool performance.
UNPACKING
When unpacking your Tile Saw make sure that the item is intact and undamaged. If any
parts are missing or broken, please call HARBOR FREIGHT TOOLS at 1-800-444-3353.