Crestron electronic GLS-ODT-W-1200 Stud Sensor User Manual


 
FCC Compliance Statement:
This device complies with part 15 and part 18 of the FCC rules. Operation is subject to the following
two conditions: (1) This device must not cause harmful interference, and (2) This device must accept
any interference received, including interference that may cause undesired operation.
Further Inquiries
If you cannot locate specific information or have questions after reviewing this guide, please take
advantage of Crestron's award winning customer service team by calling Crestron at 1-888-CRESTRON
[1-888-273-7876].
You can also log onto the online help section of the Crestron website (www.crestron.com/onlinehelp) to
ask questions about Crestron products. First-time users will need to establish a user account to fully
benefit from all available features.
Future Updates
As Crestron improves functions, adds new features and extends the capabilities of the GLS-ODT-W-1200
units, additional information may be made available as manual updates. These updates are solely
electronic and serve as intermediary supplements prior to the release of a complete technical
documentation revision.
Check the Crestron website periodically for manual update availability and its relevance. Updates are
identified as an “Addendum” in the Download column.
INSTALLATION INSTRUCTIONS
These instructions include three typical installation options (A, B and C). Choose one that
best suits your needs. Other methods may be possible but they are not described here.
Parts Supplied
Sensor (1)
#8-32 x 1/2” screw (2)
#8-32 x 1-1/2” screw (2)
#8x32 Washer and Nut (2)
Tools/Equipment Required (not supplied)
Slotted/Phillips Screwdriver Electrical Tape
Pliers Pencil
Diagonal Cutters
Model/Features
The Occupancy Sensor is a low-voltage infrared and ultrasonic sensor that works with the
GLS-SIM (or other compatible interface) to automatically control lighting. The exact behavior
of the sensor can be configured via software, but the sensor is typically used to turn lights on
when a room or area is occupied, and to shut them off when the room or area is vacated.
The sensor continually analyzes and adjusts to changing conditions. The sensor uses the
latest microprocessor-based technology which permits it to continually adjust and optimize its
performance. The combination of ultrasonic (doppler shift) motion detection, which gives
maximum sensitivity, and infrared motion detection, which gives higher false triggering
immunity, yields a sensor with excellent performance.
DESCRIPTION
To be installed and/or used in accordance with appropriate electrical codes and regulations.
If you are unsure about any part of these instructions, consult a qualified electrician.
Sensors must be mounted on a vibration free surface.
All sensors must be mounted at least 6 feet away from air vents.
Do not mount sensors closer than 10 feet from each other.
Do not touch the inner surface of the lens. Clean outer surface with a damp cloth only.
WARNINGS, CAUTIONS & NOTES
When wiring the Cresnet
®
network, consider the following:
Use Crestron Certified Wire.
Use Crestron power supplies for Crestron equipment.
Provide sufficient power to the system.
NETWORK WIRING
CAUTION: Insufficient power can lead to unpredictable results or damage to the
equipment. Please use the Crestron Power Calculator to help calculate how much power
is needed for the system. (www.crestron.com/calculators).
WARNING: To avoid fire, shock, or death; turn off power at circuit breaker or fuse and
test that power is off before wiring!
NOTES: Observe the following points regarding sensor installation.
PREPARING AND CONNECTING WIRES
Strip the ends of the wires approximately 1/2”. Use care to avoid nicking the conductors. Twist together
the ends of the wires that share a connection and tin the twisted connection. Apply solder only to the
ends of the twisted wires. Avoid tinning too far up the wires or the end becomes brittle.
Crestron GLS-ODT-W-1200
DUAL-TECHNOLOGY WALL MOUNTED
OCCUPANCY SENSOR
Operations & Installation Guide
Coverage
1200 sq. ft
Suggested
Mounting Location
Mount in corner/
over doorway
Model No.
GLS-ODT-W-1200
Description
1-Way Dual-Technology
Operating
Frequency
32KHz
Current
Consumption
30mA
MOUNTING LOCATION DIAGRAM
Mounting to Drop Ceiling Using
Screws, Nuts, and Washers
OPTION A. Wallboard or Drop Ceiling Installation Using Screws
NOTE: You may use the mounting screws, nuts and washers included, or screws in
combination with commercially available wall anchors.
1. Select the location for mounting of the sensor for your application. (Refer to Mounting
Location Diagram).
2. Make a hole in the wallboard or ceiling tile large enough to pass the wire connections
and wire nuts through (approximately 1" diameter).
3. Drill holes for monting screws using mounting bracket as a guide.
4. Install the mounting bracket of the wall sensor to the wallboard or ceiling using the
included screws, nuts and washers.
5. Pass wires through the base cover/neck assembly. (Refer to the suggested mounting
option illustrations below.)
6. Connect low voltage wires from the GLS-SIM or other Crestron
®
device as shown in the
wiring diagram. Twist strands of each lead tightly and, with circuit conductors, push firmly
into appropriate wire connector. Screw connectors on clockwise making sure that no
bare conductor shows below the wire connectors. Secure each connector with electrical
tape.
7. Push wire connections through the center hole of the back cover and into the wall or
ceiling.
8. Snap neck and base cover onto mounting bracket in the desired orientation.
9. Push wires through the hole and begin to fasten the plastic nut around the back of the
sensor body. Move the sensor body to the desired orientation and then continue to
tighten the nut around the sensor body.
10. Restore power at the circuit breaker or fuse. INSTALLATION IS COMPLETE.
OPTION B. Wallboard or Drop Ceiling Installation Using Back Box
OPTION C. Surface Mount Raceway Installation
Mounting to Octagon Back Box Installed Flush to Drop Ceiling
TYPICAL APPLICATION DIAGRAMS
Up to Three
in
Parallel
The following illustration provides a typical application example.
1. Select the location for mounting of the sensor for your application.
(Refer to Mounting Location Diagram).
2. Refer to the suggested mounting option illustrations below.
Mounting to Round Fixture with Raceway for Wallboard Ceiling Installation
GLS-ODT-W-1200
GLS-SIM
(Optional)
Mounting to Wallboard Using Screws
Low-Voltage
Wires
Drop Ceiling
Sensor
Base Cover
Screw, Nut and
Washer
(2 places)
Plastic Nut
Mounting
Base
Mounting Screws
(2 places)
Mounting Base
(top view)
Low-Voltage
Wires
Wallboard Base Cover/
Neck Assembly
Sensor
Plastic Nut
Mounting Screws
(2 places)
4" Octagon
Raised Cover
4" Octagon
Raised Cover
Mounting Base
Octagon Box
4" 1 1/2" deep
Wallboard Ceiling
Mounting to Octagon Back Box Installed Flush to Wallboard
Octagon Box
4" 1 1/2" deep
Wallboard
Mounting Screws
(2 places)
Wallboard
Mounting Screws for Wire Mold Fixture
(2 places)
Wire Mold
Round Fixture
Wire Mold
Back Cover
Wire Mold
Raceway
GLS-ODT-W-1200
GLS-ODT-W-1200
GLS-SIM
(Optional)
GLS-SIM
(Optional)
GLS-SIM
(Optional)
GLS-SIM
Cresnet
®
DIN-IO8
Cresnet
®
Crestron
2-Series Control
Processor or
CLS-C6
Crestron
2-Series Control
Processor
Sensor
#1
24 1 2 G
optional
Sensor
#2
()
Red
Black
Black
Red Red
*
Blue
*
Sensor
#1
Black
Red
Blue*
Connecting Sensors to the GLS-SIM
Connecting Sensors to the DIN-IO8 or Equivalent**
All wires from sensor to GLS-SIM
must be 24 AWG, minimum.
* To incorporate the internal photocell, connect
gray wire to GLS -SIM and cap off blue wire
from sensor.
Gray* (cap off)
Gray*
(cap off)
–SENSOR–
––– NET–––
24 Y Z G
Use CRESNET
-
P or
CRESNET
-
NP wire only
GLS-SIM
Sensor
#1
optional
Sensor
#3
()
To Control
System
G 1 2 3 4
–––
NET
G 1 2 3 4
24 Y Z G
24 Y Z G
–––
To Control
System
–––
–––
I/O
DIN-IO8
NOTE: The same Crestron power supply MUST be used to
power both the sensors and the interface device (e.g., DIN-IO8).
Otherwise, there is a risk of damage to the interface device.
*To incorporate the internal photocell, connect the gray wire to
the DIN-IO8 (or other interface device) and cap off the blue wire
from the sensor.
WIRING DIAGRAMS
Black
Blue
Blue*
**The following Crestron devices may be used to
integrate the sensors into a Cresnet system by
following the schematic shown here:
DIN-IO8 DIN-AP2 PAC2 PRO2
AV2 CP2E MP2E CNXIO16
Any Crestron product with Versiports
Use CRESNET
-
P or
CRESNET
-
NP wire only
Crestron Electronics, Inc. Operations & Installation Guide-DOC. 6771A
15 Volvo Drive Rockleigh, NJ 07647 (2023018)
Tel: 888.CRESTRON 12.08
Fax: 201.767.7576 Specifications subject to
www.crestron.com change without notice.