DeVillbiss Air Power Company D26368 Air Compressor User Manual


 
16- ENG
D26368
How to Start:
1. Turn the On/Auto/Off lever to AUTO and allow tank pressure to build.
Motor will stop when tank pressure reaches cut-out pressure.
2. Pull the regulator knob out and turn clockwise to increase pressure. When
the desired pressure is reached push knob in to lock in place. The
compressor is ready for use.
NOTE: Always operate the air compressor in well-ventilated areas free of
gasoline or other combustible vapors. If the compressor is being used to
operate a sprayer DO NOT place near the spray area.
Before Each Start-Up:
1. Place On/Auto/Off lever to OFF.
2. Pull regulator knob out, turn counter-clockwise until it stops. Push knob in
to lock in place.
3. Attach hose and accessories. NOTE: The hose or accessory will require a
quick connect plug if the air outlet is equipped with a quick connect.
Too much air pressure causes a hazardous risk of
bursting. Check the manufacturer’s maximum pressure
rating for air tools and accessories. The regulator outlet pressure must
never exceed the maximum pressure rating.
3. Open the drain valve fully (counter-clockwise) to permit air to escape and
prevent air pressure build up in the air tank during the break-in period.
NOTE: Always drain tank on a washable surface or in a suitable container to
prevent damaging or staining surfaces.
4. Move the On/Auto/Off lever to "ON/AUTO" position. The compressor will
start.
5. Run the compressor for 15 minutes. Make sure the drain valve is open and
there is minimal air pressure build-up in tank.
6. After 15 minutes, close the drain valve (clockwise). The air receiver will fill
to cut-out pressure and the motor will stop.