SERVICE INSTRUCTIONS
Motor Pulley and Flywheel
Alignment
1. Remove outer beltguard - To remove, loosen and
remove beltguard screws located at top of beltguard.
Insert a flat bladed screwdriver and pry beltguard
apart.
2. Place a straight edge along the outside face of the
compressor flywheel to check alignment of V-belt
grooves. (See figure below for proper alignment.)
3. If the belt grooves aren't aligned, continue with step
4 of this procedure. If the belt grooves are aligned,
continue with step 6 of this procedure.
4. Loosen pulley set screw and adjust pulley until it is in
proper alignment.
5. Tighten pulley set screw to 145-165 in.-lbs.
6. Reinstall belt guard.
Additional Service
Disassembly or service of the air compressor beyond
what is covered in this manual is not recommended.
If additional service is required, contact your nearest
Authorized Warranty Service Center.
STORAGE OF COMPRESSOR OUTFIT
1. Review the Maintenance section on the preceding
pages and perform scheduled maintenance as
necessary. Drain the water from the air tank.
2. Turn compressor off and disconnect or lock out
power source.
3. Remove any air tool or accessory.
4. Protect the electrical cord and/or air hose from
damage (such as being stepped on or run over).
5. Store the compressor in a clean and dry location.