DeVillbiss Air Power Company L10120H2-2 Air Compressor User Manual


 
6—ENG
MGP-SL10120H-2A
Refer to cover page for the specifications of your compressor. Use only a fuse or circuit breaker that is the same rating
as the branch circuit the air compressor is operated on. If the compressor is connected to a circuit protected by fuses,
use dual element time delay fuses, as noted in specification chart.
SPECIFICATIONS
GLOSSARY
CFM:CFM:
CFM:CFM:
CFM: Cubic feet per minute.
SCFM:SCFM:
SCFM:SCFM:
SCFM: Standard cubic feet per minute; a unit of
measure of air delivery.
PSIG: PSIG:
PSIG: PSIG:
PSIG: Pounds per square inch gauge; a unit of measure
of pressure.
ASME:ASME:
ASME:ASME:
ASME: American Society of Mechanical Engineers;
made, tested, inspected and registered to meet the
standards of the ASME.
California CodeCalifornia Code
California CodeCalifornia Code
California Code: Unit may comply with California
Code 462 (l) (2)/(M) (2). Specification/Model Label is on
the side of the tank on units that comply with California
Code.
Cut-In Pressure:Cut-In Pressure:
Cut-In Pressure:Cut-In Pressure:
Cut-In Pressure: While the motor is off, air tank
pressure drops as you continue to use your accessory.
When the tank pressure drops to a certain low level the
motor will restart automatically. The low pressure at
which the motor automatically re-starts is called “cut-
in pressure.”
Cut-Out Pressure: Cut-Out Pressure:
Cut-Out Pressure: Cut-Out Pressure:
Cut-Out Pressure: When you turn on your air com-
pressor and it begins to run, air pressure in the air tank
begins to build. It builds to a certain high pressure
before the motor automatically shuts off - protecting
your air tank from pressure higher than its capacity. The
high pressure at which the motor shuts off is called "cut-
out pressure."
To Lock Out Power:To Lock Out Power:
To Lock Out Power:To Lock Out Power:
To Lock Out Power: Place a lock on the line power
switch so no one else can turn on the power.
DUTY CYCLE
All DeVilbiss Air Power manufactured air compressors
should be operated on not more than a 50% duty cycle.
This means an air compressor that pumps more than
50% of one hour, is considered misuse, because the air
compressor is undersized for the required air demand.
Maximum compressor pumping time per hour is 30
minutes.
Improper electrical installation of this product
may void its warranty and your fire insurance.
Have circuit wiring performed by qualified per-
sonnel such as a licensed electrician who is
familiar with the current national electric code
and any prevailing local electrical codes.