Part Tests
The Part Tests section is used to dene limits for the
weld proocess and welder behavior for cases where the
process is outside the limits.
The Process Limits button is used to enter limits for
weld process results as shown in Figures 5-25, 5-26,
and 5-27. The following limits are available:
1. Weld Time (s)
2. Weld Rotations
3. Orientation (Deg.)
4. Weld Energy (J)
5. Peak RPM
6. Peak Torque (% of max.)
7. Peak Thrust (% of max.)
8. Cycle Time (s)
9. Vertical Weld End (mm)
10. Hold Collapse (mm)
11. Hold End Position (mm)
To enable a limit, press the ON/OFF box to the left of the
description and enter the Lower and Upper values. Any
combination of limits can be enabled simultaneously.
The More Limits… button shows additional limits, and
the DONE button causes the screen to return to the
POST-WELD main menu.
Figure 5–25 Process Limit Denitions Screen 1 of 3