Duracell Ultra 223 Battery Charger User Manual


 
Lithium/Manganese Dioxide
Ultra 223
Li/MnO2
This data is subject to change. Performance information is typical. Contact Duracell for the latest information
Delivered capacity is dependent on the applied load, operating temperature and cut-off voltage. Please refer to the charts
and discharge data shown for examples of the energy / service life that the battery will provide for various load conditions.
**
6/08
Dimensions shown are IEC/ANSI standards
Duracell Ultra 223 Typical Performance
0 500 1000 1500 2000
Pulse Cycles
Photo
35mm SLR Photo
35mm Point &
Shoot Camera
1.2A, 3 sec on 7sec off, cont.
to 3.6 V @ 20°C
1.8A, 3 sec on 7sec off, cont.
to 3.6 V @ 20°C
0.9A, 3 sec on 27sec off, cont.
to 3.6 V @ 20°C
36.0
34.5
mm
35.0
32.5
mm
16.8 mm
REF.
19.5
18.5
mm
( + )
( – )
Nominal Voltage: 6 V
Typical Voltage: 6.4-6.6 V
Nominal Internal
Impedance:
0.4 ohm @ 1kHz
Average Weight: 38 gm
Typical Volume: 22.6 cm
3
Terminals:
Flat, Recessed Contacts
Nickel Plated Steel
Operating Temperature
Range:
-20
o
C to 75
o
C
(-4
o
F to 167
o
F)
NEDA/ANSI:
IEC:
5024LC
CR-P2
Delivered Energy vs. Power Drain
@ Various Cutoff Voltage - Room Temperature
4
10
0.2
1
4
Power (W)
Energy (Wh)
3.6 V
4.0 V
4.4 V