Fujitsu CM25-00322-1E Saw User Manual


 
232
CHAPTER 4 MENUS
[Simulator]
Figure 4.6-2 Break Dialog Box (Code)
- Breakpoint address
In this field, the address that sets a breakpoint is specified.
- Remaining count
The remaining count of settable breakpoint is displayed.
- Pass count
In this field, the count of times the PC passes that point (a particular point) before causing a break is
set. This field is only enabled for the simulator.
- Breakpoint list
A list of code breakpoints currently being set is displayed.
State : Enable or disable is displayed.
Type : The breakpoint type is displayed.
Address : The set address is displayed.
Attribute : The breakpoint attribute is displayed.
Pass count : The set pass count is displayed. In ( ), the count of times the PC has passed that
point by the present time is displayed.
Symbol : The symbol given to that address is displayed.
- [Setting] button
These buttons are used to set a breakpoint at the specified address. When an address that is already set
in the breakpoint list is specified, the set data of the breakpoint at this address is changed.