Graco Inc. 02748 Paint Sprayer User Manual


 
308-3415
Air
Flow and Atomizing Pressure
NOTE:
All tests completed with the fan air fully open.
Air Flow
0
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
15 25 35 45 55 65 75 85 95
AIR FLOW (scfm)
GUN
AIR INLET PRESSURE (psi)
Atomizing Pressure Versus
Activator Inlet Pressure
Air
flowing through the gun creates back pressure,
which the activator must overcome before beginning to
flow
. The chart below shows the minimum activator
pressure required to overcome the atomizing air
pressure. Higher pressures may be necessary to
maintain the mix ratio.
GUN
AIR INLET PRESSURE (psi)
0
2
4
6
8
10
12
14
16
18
20
22
24
26
28
30
15 25 35 45 55 65 75 85 95
MINIMUM
ACTIVAT
OR INLET PRESSURE (psi)
Atomizing Air Pressure
(inlet pressure vs. atomizing pressure)
GUN
AIR INLET PRESSURE (psi)
0
2
4
6
8
10
12
14
16
18
20
15 25 35 45 55 65 75 85 95
NOMINAL
AT
OMIZING PRESSURE (psi)
Gun
Inlet Pressure
Nominal Atomizing Pressure
15 psi (1.05 bar)
1.5 psi (0.1
1 bar)
25 psi (1.75 bar)
3.0 psi (0.22 bar)
35 psi (2.45 bar)
4.5 psi (0.33 bar)
45 psi (3.15 bar)
6.0 psi (0.42 bar)
55 psi (3.85 bar)
8.5 psi (0.62 bar)
65 psi (4.55 bar)*
10.0 psi (0.70 bar)
75 psi (5.25 bar)
13.0 psi (0.95 bar)
85 psi (5.95 bar)
15.5 psi (1.14 bar)
95 psi (6.97 bar)
18.0 psi (1.32 bar)
*
For compliant operation, operate at 65 psi (4.55 bar) or less