Graco Inc. 111418a Paint Sprayer User Manual


 
Cleanup
310892F 25
9. Hold gun against mate-
rial pail. Take trigger
safety OFF. Turn pres-
sure control up until
motor begins to drive
pump. Trigger gun until
flushing fluid appears.
10. Move gun to flushing
pail, hold gun against
pail, trigger gun to thor-
oughly flush system.
Release trigger and put
trigger safety ON.
11. Turn prime valve down
and allow flushing fluid
to circulate for approxi-
mately 20 seconds to
clean drain tube.
12. Raise siphon tube above
flushing fluid and run
sprayer for 15 to 30 sec-
onds to drain fluid. Turn
pump switch OFF. Turn
engine OFF.
-!4%2)!,
ti5890a
FLUSH
ti5981a
20 SEC
ti5838a
-!4%2)!,
&,53(
ti5822a
/&&
ti5827b
OFF
/&&
/.