Requirements
• The light control requires 120-volts AC.
• This fixture is designed for wall mounting only.
• If you want to use Manual Override, the control must
be wired through a switch.
Some codes require installation by a qualified
electrician.
• This product is intended for use with the enclosed
gasket and with a junction box marked for use in wet
locations.
• The backplate has knockouts so the sensor can be
mounted on most junction boxes.
• In some applications a universal adaptor plate may
be needed. Adaptors are available at Home Centers
and Electrical Supply Stores.
S-hook
1 Halogen
Lamp
Model SH-5311
3 Wire
Connectors
6 Screws
(3 sizes included)
This package includes:
OPERATION
* resets to Auto Mode at dawn.
TEST
10 5 1 TEST
ON-TIME
Put the ON-TIME switch on the
bottom of the sensor in the TEST
position.
MANUAL MODE
ON-TIME
10 5 1 TEST
... back on.
AUTO
1 Second OFF
then...
Note: When first turned on wait about 1
1
/
2
minutes for
the circuitry to calibrate.
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 10
position.
Put the ON-TIME switch in the 1, 5,
or 10 minute position.
Mode: On-Time: Works: Day Night
Test
5 Sec x x
Normal
1, 5, 10 min. x
Manual
Until Dawn* x
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Bulb Saver™ - Extends bulb life by up to 4x standard
bulbs. Lights bulb to full bright in under 2 seconds.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
Professional Motion Sensor
Quartz Security Light