Heath Zenith SL-5326 Work Light User Manual


 
Model SL-5326
DualBrite
®
Motion
Sensor Light Control
with 2-Level Lighting
© 2006 DESA Specialty Products
598-1269-00
TEST
2 Shells*
Features
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Softstart lighting technology slowly increases light
intensity when lights turn on and slowly decreases
light intensity when lights turn off.
DualBrite
®
Timer.
• Photocell keeps the lighting off during daylight hours.
• LED indicates motion was sensed (day or night).
TEST 1 5 20
ON-TIME
Off 3 6 Dusk to
Dawn
DualBrite
®
Put ON-TIME switch
on the sensor bottom
to TEST and the Dual-
Brite
®
switch OFF.
DualBrite
®
TIMER
Light comes on half bright for selected time after dusk
(Off, 3 hr., 6 hr., until dawn). If motion is sensed,
the light turns on full bright for the ON-TIME (1, 5,
or 20 minutes) then returns to dim mode.
Mode: On-Time: Works: Day Night
Test 5 Sec x x
Auto 1, 5, 20 min. x
Manual Until Dawn* x
OPERATION
* resets to Auto Mode at dawn.
MANUAL MODE
ON-TIME
TEST 1 5 20
... back on.
AUTO
1 Second OFF
then...
Put the ON-TIME switch in the 1, 5,
or 20 minute position.
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Flip the light switch off for one second
then back on to toggle between AUTO
and MANUAL MODE.
Manual mode works only with the
ON-TIME switch in the 1, 5, or 20
position.
Move ON-TIME Switch to
1, 5, or 20 minutes
Mode Switching Summary
Flip light switch off
for one second then
back on*
MANUAL MODE
AUTO
TEST
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the cali-
bration time the control will be in the AUTO mode.
Note: When first turned on wait about 1
1
/
2
minutes for
the circuitry to calibrate.
This package includes:
Light Control
Sensor
Cover
Plate
Lamp
Holders
Plastic Hanger
Rubber Plug
Gasket
6 Screws
(3 sizes included)
Mounting Strap
Mounting Bolt
2 Wire
Connectors
Requirements
• The Light Control requires 120-volts AC.
• If you want to use Manual Mode, the control must be
wired through a switch.
Some codes require installation by a
qualified electrician.
• This product is intended for use with the enclosed
gasket and with a junction box marked for use in wet
locations.