10 OM-185 158
2.3 Volt-Ampere Curves
ssb1.1 10/91 – SB-144 925-A / S-0700-A
1 Normal Volt-Ampere Curves
The volt-ampere curves show the
normal minimum and maximum
voltage and amperage output capa-
bilities of the welding power source.
Curves of other settings fall be-
tween the curves shown.
2 Overload Volt-Ampere Curves
When unit is used beyond capacity,
circuitry senses the overload and
shuts down unit output. Release
trigger and lower weld voltage set-
ting before trying to weld. This shut
down circuitry protects internal
circuits and parts from overload
damage.
0
10
20
30
40
50
60
0 50 100 150 200 250 300 350 400
DC VOLTS
DC AMPERES
1
*
*
*Approximate shutdown voltage/amperage
points shown for reference only.
2
2.4 Installing Running Gear
ST-801 856-A
Install running gear as shown.
Tools Needed: