631 Airport Road, Fall River, MA 02720 • (508) 679-8131 • Fax (508) 674-4710
We reserve the right to change details of design, materials and finish.
www.lightolier.com © 2008 Philips Group • D0308
Job Information Type:
Job Name:
Cat. No.:
Lamp(s):
Notes:
FBP Series Fluorescent Emergency Ballast FBP50
Page 1 of 1 One or Two Lamp Operation 1,400 Lumens
Lightolier is a Philips group brand
The FBP Series quickly converts standard fluorescent luminaires into emergency luminaires.
13.3”
(33.9 cm)
2.4”
(6.1 cm)
1.5”
(3.8 cm)
Complete Fixture consists of ballast unit. Select options and accessories below.
Model # Max. Lumens Lamp Operation
FBP50 1,400 One or Two
Lamp Operation and Performance (continued)
Non-Emer. Emer. Op.
Max. Max. Emer.
Lamp Base Lumen Lumen Lamp
Type Watt. Type Output Output Operation
F96T12HO 95 R17D/Recessed 8000 1100 - 1400 One
F48T12 110 R17D/Recessed 6200 1100 - 1400 One
F17T8 17 G13/Med Bi-Pin 1325 1100 - 1400 One or Two
F25T8 25 G13/Med Bi-Pin 2080 1100 - 1400 One or Two
F32T8 32 G13/Med Bi-Pin 2850 1100 - 1400 One or Two
F32T8/U 32 G13/Med Bi-Pin 2700 1100 - 1400 One or Two
F40T8 40 G13/Med Bi-Pin 3600 1100 - 1400 One
F96T8 59 FA8/Single-Pin 5800 1100 - 1400 One
F27BX 27 2G11/4--Pin 1800 1000 Two
F282D 28 GR10Q-4/4 Pin 2050 1100 One or Two
F382D 38 GR10Q-4/4 Pin 2850 1000 One or Two
F39/36BX 39 2G11/4--Pin 2850 1100 One or Two
F40/30BX 40 2G11/4--Pin 3150 1100 One
F50BX/FT55 50-55 2G11/4--Pin 4300-4800 1100 One or Two
F96T12HO 95 R17D/Recessed 8000 1100 - 1400 One
F96T12VHO 95 R17D/Recessed 8000 1100 - 1400 One
Notes:
1. Maximum non-emergency lumen output can vary based on lamp manufacturer, ambient
operating temperature, and ballast manufacturer.
2. Maximum emergency lumen output is based on total output of one or two lamps, and can
vary based on lamp manufacturer and ambient operating temperature.
3. Maximum emergency lumen output is supported for a full 90 minutes of operation.
4. Consult factory for compatibility, operation and performance of lamp types not listed.
Features
1. Lamp Operation: Operates the following lamp types: T8 linear fluorescent,
T12 linear fluorescent, T9 circline, T12 U-bent, T5 long compact fluorescent,
compact 4-pin fluorescent. See Lamp Operation and Performance table for
specific lamp performance and operation.
2. Illumination: Provides 90 minutes of emergency illumination, and produces
a maximum of 1,100 to 1,400 lumens initial emergency light output. Can be
used with most 17w to 215w (2’ - 8’) T8, T10 or T12 fluorescent lamps with-
out integral starters including U-shaped, HO, VHO, circline, energy saving,
and 4 pin compacts. It is also compatible with most 1, 2, 3 and 4-lamp elec-
tronic, standard, energy saving and dimming AC ballasts.
3. Housing: Constructed of 20 gauge steel with a high temperature powder
coat paint finish. Slim housing allows for wireway channel mounting on most
recessed luminaires.
4. Electronics: 120/277 VAC dual voltage input with surge-protected, solid-
state circuitry. Charging system is complete with AC indicator lamp and test
switch.
5. Battery: Maintenance free, sealed nickel cadmium battery has an estimated
service life of 10 years, and an operating temperature range of 32°F (0°C) to
131°F (55°C).
6. Input Power Requirements: 4 watts max.
7. Warranty: Electronics: 5 years; Battery: 5 years.
Code Compliance
UL 924 listed, damp location listing optional.
UL listed for use within sealed and/or gasketed luminaires.
Options
EX = Special Input Transformer for 220 VAC/50 Hz, 240 VAC/50Hz.
Contact factory for other input voltages and frequencies.
DL = UL Damp Location Listing
Accessories
CCAPS = Wire bundle cover for mounting external to luminaire.
RTS = Single gang aluminum faceplate pre-drilled to accommodate remote
installation of test switch and pilot light.
Lamp Operation and Performance
Non-Emer. Emer. Op.
Max. Max. Emer.
Lamp Base Lumen Lumen Lamp
Type Watt. Type Output Output Operation
F20T12 20 G13/Med Bi-Pin 1275 1100 - 1400 One or Two
F30T12 30 G13/Med Bi-Pin 2350 1100 - 1400 One or Two
F40T12 40 G13/Med Bi-Pin 2650 1100 - 1400 One or Two
F40T12/U 40 G13/Med Bi-Pin 3100 1100 - 1400 One or Two
F48T12 40 FA8/Single-Pin 2875 1100 - 1400 One or Two
F60T12 50 FA8/Single-Pin 3600 1100 - 1400 One
F72T12 55 FA8/Single-Pin 4500 1100 - 1400 One
F96T12 75 FA8/Single-Pin 5500 1100 - 1400 One
F24T12HO 35 R17D/Recessed 1620 1100 - 1400 One
F36T12HO 45 R17D/Recessed 2800 1100 - 1400 One
F48T12HO 60 R17D/Recessed 5150 1100 - 1400 One
F60T12HO 75 R17D/Recessed 4050 1100 - 1400 One
F72T12HO 85 R17D/Recessed 6350 1100 - 1400 One
Nickel Cadmium Battery