Lincoln Electric US-F146 Welder User Manual


 
Date:
11/1/2007
MSDS No.:
US-F146
Trade Name:
Lincolnweld 880M
Sizes:
---
Supersedes:
11/1/2004
M A T E R I A L S A F E T Y D A T A S H E E T
For Welding Consumables and Related Products
Conforms to Hazard Communication Standard 29CFR 1910.1200 Rev. October 1988
SECTION I - IDENTIFICATION
Product Type: Submerged Arc Flux
Manufacturer/
Supplier:
The Lincoln Electric Company
22801 St. Clair Avenue
Cleveland, OH 44117-1199
(216) 481-8100
Classification:
AWS F7A8-EM13K-H8 F8P2-ECB2-B2-H8
F7A8-ENi1K-Ni1-H8 (with LAC-B2)
F9A6-EA3K-A3-H8 F11A6-ECM2-M2-H8
F8P8-EA3K-A3-H8 (with LAC-M2)
F9A6-EM2-M2-H8 F7A10-ECNi2-Ni2-H8
F7A6-EH12K-H8 (with LAC-Ni2)
F7P10-ECNi2-Ni2-H8
(
with LAC-Ni2
)
SECTION II - HAZARDOUS MATERIAL (1)
I M P O R T A N T !
This section covers the materials from which this product is manufactured. The fumes and gases produced during welding with the normal
use of this product are covered by Section V; see it for industrial hygiene information.
CAS Number shown is representative for the ingredients listed.
(1) The term “hazardous” in “Hazardous Materials” should be interpreted as a term required and defined in the Hazards Communication
Standard and does not necessarily imply the existence of any hazard. All materials are listed on the TSCA inventory.
Ingredients: CAS No. Wt.%
TLV
mg/m
3
PEL
mg/m
3
Magnesite 1309-48-4 30 10 15
Aluminum oxide and/or Bauxite 1344-28-1 15 10 15
Fluorides (as F) 7789-75-5 15 2.5 2.5
Mineral silicates 1332-58-7 10 5** 5**
Silicates and other binders 1344-09-8 5 10* 10*
Limestone and/or calcium carbonate 1317-65-3 < 5 10 15
Manganese and/or manganese alloys and compounds (as Mn)***** 7439-96-5 1 0.2 5 (c)
Silicon and/or silicon alloys and compounds (as Si) 7440-21-3 < 0.5 10* 10*
Iron 7439-89-6 < 0.5 10* 10*
Supplemental Information: (*) Not listed. Nuisance value maximum
is 10 milligrams per cubic meter. PEL value for iron oxide is 10 milligrams per
cubic meter. TLV value for iron oxide is 5 milligrams per cubic meter.
(**) As respirable dust. Value for respirable quartz is 0.05 milligrams per
cubic meter.
(*****) Subject to the reporting requirements of Sections
311, 312, and 313 of the Emergency Planning and
Community Right-to-Know Act of 1986 and of
40CFR 370 and 372.
(c) Value is for manganese fume. Present PEL is 5
milligrams per cubic meter (ceiling value). Values
proposed by OSHA in 1989 were 1.0 milligrams per
cubic meter TWA and 3.0 milligrams per cubic meter
STEL (Short Term Exposure Limit).
SECTION III - HAZARD DATA
Non Flammable; Welding arc and sparks can ignite combustibles and flammable products. See Z49.1 referenced in Section VI.
Product is inert, no special handling or spill procedures required. Not regulated by DOT.
Rev 4/07 (CONTINUED ON SIDE TWO)