b) Welding Output
Box 6 Welding process Symbol e.g.:
Manual metal arc welding with covered electrodes
Tungsten inert-gas welding
Metal inert and active gas welding including the use of flux cored wire
Selfshielded flux cored arc welding
Submerged arc welding
Symbol for plasma cutting
Symbol for plasma gouging
Box 7 Symbol for welding power sources which are suitable for supplying power to welding operations
carried out in an environment with increased hazard of electric shock (if applicable).
Box 8 Welding current symbol e.g.:
Direct current
Alternating current, and additionally the rated frequency in
hertz e.g.: ~50 Hz
Box 9 U
0
... V Rated no-load voltage
a) Arithmetic mean value in case of direct current
b) RMS value in case of alternating current
c) U
r
... V Reduced rated no-load voltage in case of a voltage reducing device
d) U
s
... V Switched rated no-load voltage in case of an a.c. to d.c. switching device
Box 10 ... A/... V to... A/... V Range of output, rated minimum and maximum welding current and their
corresponding conventional load voltage.
Box 11 X Duty cycle (duty factor) symbol.
Box 12 I
2
Rated welding current symbol.
Box 13 U
2
Conventional load voltage symbol.
Boxes 11a, 11b, 11c ...% Values of the duty cycle (duty factor).
12a, 12b, 12c ... A Values of the rated welding current.
13a, 13b, 13c ... V Values of the conventional load voltage.
These boxes form a table with corresponding values of the three settings:
a) ... % duty cycle (duty factor) at the rated maximum welding current;
b) 60 % duty cycle (duty factor);
and
c) 100 % duty cycle (duty factor) as far as relevant.