SECTION 6 SETTING SEQUENCE PARAMETERS
6-1. Sequence Parameters In A Program
. See Menu Guide for detailed
programming steps.
Trim is arc length. If set to zero, arc
length is short. If set to 99, arc
length is long.
If time is set to zero in Weld
sequence, welding continues until
gun trigger is released.
If time is set to zero in any timed
sequence except Weld, the
sequence is skipped.
Trigger
Pressed
Trigger
Released
Wire Speed
Time
Start
Time
Preflow
Run-In WFS
Weld WFS
Weld Time
Crater WFS
Crater
Time
Postflow
Arc
Strike
Burnback
Time
Time
Time
PostflowCrater
WeldRun-In
Preflow
Burnback
Sequence
End
Trim
0-99
Volts
10.0-38.0
Inductance
0-99%
IPM
50-780
Seconds
1. Weld
2. Crater
3. Burnback
4. & 5. Postflow/
Preflow
6. Run-In
Pulse
MIG
Pulse
MIG
MIG
0-100.0
0-5.00
0-0.25
0-9.9
X
XX X
X
XX
X
25-780
X
X
X = Setting available.
Pulse
6. Start
Pulse
MIG
0.00-5.00XX
XX
0-100 sec.