Miller Electric DS-64M Swingarc Welder User Manual


 
OM-1588 Page 32
SECTION 12 SETTING SharpArcE CONTROL
12-1. Selecting And Adjusting SharpArcE Control
Ref. S-0259
1 Arc
SharpArc is “Arc” on the display.
It is used to adjust arc cone width
and arc characteristics.
Use front panel parameter select
button to move > to select Arc. Use
Display Control to adjust Arc
setting.
SharpArc setting range is from 0
to 20. The factory default is set at
zero (0). When Arc value is
increased toward 20, the arc cone
narrows and the weld puddle
becomes less fluid.
50 Tr im
200 IPM
>Pr g 1
035“St
50 Tr im
200 IPM
Prg 1
>Ar c 0
1
Parameter
Select
50 Tr im
200 IPM
Prg 1
>Ar c20