14-3. Error Displays
Ref. ST-155 222
1 Release Trigger Error Display
This appears if the trigger is closed
when the unit power is turned on, or
if the trigger is stuck or defective.
2 No Volt Sensed Error Display
The arc voltage sense circuit is not
receiving feedback. Check voltage
sensing connections. Check
connections at 14-position plugs/
receptacles at the unit and welding
power source.
Turn unit off and back on after
correcting problem.
If this error continues to occur when
pulse welding, it may help to select
Hot Start.
3 Memory CRC Error Display
The data in the program indicated is
not the same data that was saved.
Perform a system reset.
4 Memory Range Error Display
The data in the program indicated is
out of usable range.
Go through pulse parameters to
make sure they do not exceed
settings of the Range display or per-
form a system reset.
5 No Tach Sensed Error Display
The motor tach feedback is not
reaching the control. Check
connections.
Press front panel Parameter Select
to clear error.
6 Arc Start Error Display
This appears when pulse welding
and current is detected but the arc
cannot be started. Check and
correct program pulse parameters
and voltage settings. Check voltage
sensing connections.
Press front panel Parameter Select
to clear error.
7 Arc Stop Error Display
This appears when pulse welding
and the motor does not stop at the
end of the weld. If there is high
frequency being used in the area,
turn it off. A motor brake circuit prob-
lem can also cause this error.
Press front panel Parameter Select
to clear error.
8 Minimum Gas Flow Error
This appears when gas flow falls
below the minimum CFH set (xx in
example). Adjust gas flow to bring it
above set value.
Press front panel Parameter Select
to clear error.
9 Maximum Gas Flow Error
This appears when gas flow is
above the maximum CFH set (xx in
example). Adjust gas flow to bring it
below set value.
Press front panel Parameter Select
to clear error.
10 Gas Out Of Range Error
This appears when gas flow is
greater than 100 CFH. To protect
the internal sensor, the unit shuts
down until the gas flow can be
adjusted below 100 CFH.
11 Coolant Flow Error
This appears only when coolant
flow switch option is installed.
Check coolant recirculating
system.
12 Unlocked Program Error
Display
This appears when attempting to
run an unlocked program while
other programs are locked. Either
lock the unlocked program or select
a different program that is locked.
Re l ease
Tr igger
1
No Vo l t
Sensed Er r or
Memo r y
CRC
Prg 1
Er ror
3
4
Memo r y
Range
Prg 1
Er ror
2
No Tach
Sensed Er r or
Arc
Star t Error
Arc
Stop Error
5
6
7
Mi n C F H x x
Ga s F l o w E r r o r
Ma x C F H x x
GasF l ow E r r o r
Gas Ou t
ofRange Er ror
Coo l an t
Flow Error
11
8
9
10
Un l ocked
Program Er ror
12