Omega Vehicle Security DP25-TH Stud Sensor User Manual


 
Using This Quick Start Manual
Use this Quick Start Manual to set up your controller
and begin operation. Information is provided on how to:
¥ Connect ac power
¥ Connect sensor input
¥ Set basic options for operation
For complete information on all setup options, see the
OperatorÕs Manual.
Before You Begin
In addition to the controller and the related parts, you
will need the following items to set up your unit:
¥ ac power
¥ Sensor
¥
1
Ú8Ó flat blade screwdriver
Mount the Meter
1. Cut a panel opening
using the dimensions
shown to the right.
2. Position the unit in the
opening, making sure
the front bezel is flush with the panel.
Connect ac Power
Warning: Do not connect ac power to your meter
until you have completed all input and output
connections. Failure to do so may result in injury!
1. Remove the panel at the back of the unit.
2. Locate the TB1 connector.
3. Insert the correct wire in each terminal as shown
in the following figure and tighten the lockdown
screws. Tug gently on the wires to verify
connections.
Main ac Power Connections
To Change the Input Type:
1. Press MENU until the display
shows ÒINPTÓ:
2. Press
/MIN to show current input
type:
3. Press
/MAX to select the setting.
Choices are: 4004, 4005, 4006,
4007, 4008, 4017, 4018 and 700.
4. Press MENU to store the value.
5. Press RESET twice to display the current
temperature.
To Change the Decimal Point:
1. Press MENU until the display
shows ÒDEC.PÓ:
2. Press
/MIN to show the current
decimal point location:
3. Press
/MAX to select the setting.
Choices are: ÒFFF.FÓ, ÒFFFF.Ó or
ÒFF.FFÓ.
4. Press MENU to store the value.
5. Press RESET twice to display the current
temperature.
Turn on the Unit
1. Apply power to the unit. The unit initializes,
flashing ÒTHERMISTORÓ. Then the temperature
should appear.
2. Verify that a temperature is displayed. If not:
¥ Remove ac power
¥ Verify the TB1 power connections
¥ Check your power source
¥ Apply power again
Configure the Unit
To configure the unit, use the buttons on the controllerÕs
front panel.
To: Take This Action
Display the Press the MENU button.
Configuration The first function on the
Menu. menu, ÒINPTÓ, displays.
Select the 1. Press MENU until the
submenu function you want is shown.
function. 2. Press
/MIN.
Select a value 1. Press
/MAX. to display
for that submenu the option you want.
function. 2. Press MENU to select it.
ÒSTRDÓ quickly flashes,
indicating that the selection
has been stored in memory.
Then the next menu function
displays.
Go back to the Press RESET once.
previous menu
function.
Exit the ¥ Press RESET twice. The
Configuration unit reinitializes (displays
Menu. ÒRSTÓ, then ÒTHERMISTORÓ).
When the temperature
displays, the meter is back in
Run Mode.
¥ Optionally, you can press
MENU to move through all
the menu functions until the
meter reinitializes.
Connecting the Sensor Input
1. Locate the TB2 (TB3 on Version #1) connector on
the rear of the unit.
2. Connect sensors, referring to the appropriate
diagram below and tighten down lockdown
screws.
3. Tug gently on the wires to verify the connections.
4. Replace the panel at the back of the unit.
2-Wire Input (400 Series)
3-Wire Input (700 Series)
Hook up Alarm 1 (Setpoint) (refer to TB1 Main
ac Power Connection Drawing)
1. Connect a jumper from ac Line (Terminal 7) to
Relay 1 Common (Terminal 3).
2. Connect Relay 1 Normally Open (Terminal 1) to
External Alarm ac Line.
3. Connect External Alarm to ac Neutral (Terminal 8).
Hook up Alarm 2 (Setpoint) (refer to TB1 Main
ac Power Connection Drawing)
1. Connect a jumper from ac Line (Terminal 7) to
Relay 2 Common (Terminal 6).
2. Connect Relay 2 Normally Open (Terminal 4) to
External Alarm ac Line.
3. Connect External Alarm to ac Neutral (Terminal 8).
+S
-S
1
2
-R
3
+S
-S
1
2
-R
3
START HERE
2
34
45,00 + 0,61/-0,00
(1.772 + .024/Ð.000)
92,00 + 0,81/Ð0,00
(3.622 + .032/Ð.000)
PANEL THICKNESS
1,5
R(.06)
4 PLCS
6,4 (.25) MAX
0,8 (.03) MIN
NOTE: Dimensions in Millimeters (Inches)
VERSION #2
TB1
LINE
NEUTRAL
10 11 12
FUSE
AC POWER
EARTH
GROUND
TB1
VERSION #1
TB3
TB2
897
654321
321
10 11 12
897
654321
321
ᮡᮣ
SETPTS /MIN MENU RESET
/MAX
ᮡᮣ
SETPTS /MIN MENU RESET
/MAX
ᮡᮣ
SETPTS /MIN MENU RESET
/MAX
ᮡᮣ
SETPTS /MIN MENU RESET
/MAX
ᮡᮣ
SETPTS /MIN MENU RESET
/MAX
ᮡᮣ
SETPTS /MIN MENU RESET
/MAX
ᮡᮣ
SETPTS /MIN MENU RESET
/MAX
ᮡᮣ
SETPTS /MIN MENU RESET
/MAX
ᮡᮣ
SETPTS /MIN MENU RESET
/MAX
ᮡᮣ
SETPTS /MIN MENU RESET
/MAX