Panasonic SD48C90JBU6 Air Compressor User Manual


 
Rated Performance Data
Capacity . . . . . . . . . . . . . . 546 Btu/h ±7% *
E.E.R. . . . . . . . . . . . . . . . . . 4.67 Btu/Wh ±10% *
Current . . . . . . . . . . . . . . . 1.07 Amps *
Nominal Motor Data Motor Input . . . . . 117 Watts*
Rated Current . . . 1.16 Amps
Type . . . . . . . . . . RSCR, PTC relay
Locked Rotor . . . . . . . . . . 8.97 Amps
Start Current . . . . . . . . . . 15.73 Amps
Coil Resistances Run . . . . 3.82 Ohms
@ 68°F (20°C) Start . . . 6.66 Ohms
*Test Conditions for Performance Specifications
Test Oil . . . . . . . . . . . . . . . . Freol α 10
Shell Temp . . . . . . . . . . . . . . 150.0°F / 65.0°C
Condensing Temp . . . . . . . . . 130.0°F / 54.4°C
Evaporating Temp . . . . . . . . .-10.0°F / -23.3°C
Ambient Temp . . . . . . . . . . . . 90.0°F / 32.2°C
Gas Superheat . . . . . . . . . . . 90.0°F / 32.2°C
Liquid Sub-Cooling . . . . . . . . 90.0°F / 32.2°C
Electrical Accessories
Overload Protector
Nominal Operating Characteristics
Model Name T135AH6
.
1
Manufacturer Matsushita
Temperature To . . . . . . . . . . . Open: 275°F ± 9°F / 135°C ± 5°C
Close: 176°F ± 27°F / 80°C ± 15°C
Trip Current . . . . . . . . . . . . . . @212°F (100°C) 4.1 to 5.1 Amps
@77°F (25°C) 16.5 Amps @ 13 sec. max.
P.T.C. Starting Device
Nominal Operating Characteristics
Model Name MM8-5DCP4M7 PTH7M4R7MD2
Manufacturer Matsushita Murata Mfg.
Base resistance
@ 77°F(25°C) ±20% 4.7 4.7 Ohms
Power Consumption (max) 3.3 3.0 Watts
Operation time 1.3 to 3.0 0.7 to 2.2 seconds
Recovery time (max) 65 70 seconds
Run Capacitor 12 µF 180 V (min.)
†Although these accessories are listed by UL/CSA for use with this compressor,
Matsushita assumes no responsibility whatsoever for these or any other components
sourced by the refrigeration system manufacturer from third parties.
Panasonic Industrial Company
Refrigeration Products Department
Tel: 201 - 392 - 4249
Fax: 201 - 392 - 4315 Rev#1-5/9
Evaporating Temp.
Condensing Temp. Rating -30°F -10°F +10°F
130°F Btu/h 239 546 983
Watts 77 117 160
Amps 0.75 1.07 1.46
E.E.R. 3.10 4.67 6.14
120°F Btu/h 280 577 1,011
Watts 80 116 155
Amps 0.78 1.07 1.42
E.E.R. 3.50 4.97 6.52
110°F Btu/h 311 604 1,038
Watts 82 113 149
Amps 0.79 1.06 1.37
E.E.R. 3.79 5.35 6.97
MATSUSHITA Compressor Single Phase 115 V
MODEL# SD48C90JBU6 (VG10) R-134a 60
Hz
Performance Curves
Voltage Range . . . . . . . . . 103 Volts to 127 Volts @ 60 Hz
Application . . . . . . . . . . . . Low Back Pressure
Compressor Cooling . . . . Static Cooling
Refrigerant Control . . Capillary Tube
Evaporator
Temp. Range . . . . . . . -31°F to 23°F / -35°C to -5°C
9 – Point Data
P
a
na
s
o
n
ic
®
200
300
400
500
600
700
800
900
1,000
1,100
-30 -20 -10 0 10
Evaporating Temperature (°F)
Capacity (BTU/H)
110°F 120°F 130°F
70
90
110
130
150
170
-30 -20 -10 0 10
Input Power (W)
0.7
0.8
0.9
1.0
1.1
1.2
1.3
1.4
1.5
-30 -20 -10 0 10
Current (A)