Progressive International Paint Sprayer Paint Sprayer User Manual


 
providing "PROGRESSIVE SOLUTIONS" for your industry.
providing "PROGRESSIVE SOLUTIONS" for your industry.
PO Box 7277
Algonquin, IL 60102
800.801.7832 - 847.639.7272
support@4progressive.com
www.4progressive.com
“REAL” Pump
“REAL” Pump
Power Spraying System
Power Spraying System
- Owners Manual
- Owners Manual
rev0209
rev0209
providing "PROGRESSIVE SOLUTIONS" for your industry.
providing "PROGRESSIVE SOLUTIONS" for your industry.
PO Box 7277
Algonquin, IL 60102
800.801.7832 - 847.639.7272
support@4progressive.com
www.4progressive.com
“REAL” Pump
“REAL” Pump
Power Spraying System
Power Spraying System
- Owners Manual
- Owners Manual
rev0209
rev0209
4 1
4 1
FOR USE WITH ALL
FOR USE WITH ALL
“REAL” PUMP
“REAL” PUMP
POWER SPRAYERS
POWER SPRAYERS
Wiring Diagrams
115v AC Pump
or
(230v AC Pump)
Green (Yellow)
Ground
Wire Nut
Green (Yellow)
Ground
Power Cord
Black (Brown)
DPST
Switch
1 amp
Circuit Breaker
White (Blue)
Black (Brown)
White (Blue)
Black (Brown)
Pressure
Switch
12v DC Pump
DPST
Switch
10 amp
Circuit Breaker
Black (-)
Black (-)
Black (-)
Power Cord
Red (+)
Red (+)
Red (+)
Red (+)
Pressure
Switch
DIRECTIONS FOR USE:
1)
Position the unit on top of the container you wish to dispense from and
insert the suction hose. The brass suction nozzle has been threaded so
that a garden hose may be connected to lengthen the suction line or give
the operator the ability to spray water. The maximum vertical self prime is 15 feet.
2) Check the switch to be sure it is in the "OFF" position, then connect the power
source.
AC - Insert the plug into a grounded outlet.
DC - Connect the RED (+) clamp to the positive battery terminal. Then
connect the BLACK (-) clamp to a grounded metal portion of the
chassis or engine. For stand alone battery applications the BLACK (-)
clamp may be connected directly to the negative battery terminal.
3) Squeeze the spray control gun or remove the spray control gun. Insert end into container. Move
switch to the "ON" position and allow the unit to prime.
4) When primed, move switch to "OFF" and connect the spray control gun and wand if not already
connected. If the product must be circulated before spraying, leave unit "ON" with hose or wand end in
the container and allow product to circulate. *A bypass is available for products that need to be
continuously circulated.
DIRECTIONS FOR CLEANING: MUST BE CLEANED AFTER EVERY USE!
1) After spraying, remove the suction hose from the container. Insert the wand end into the container
and hold the spray control gun in the OPEN position. Allow the unit to expel the unused material back
into the container. The wand and the spray tip are left attached for this process to provide a back
pressure that will help expel 90% of the unused material out of the unit.
2) Then circulate either soap and water or other recommended cleaning solution through the unit until it
comes out clean and clear. NEVER USE STRAIGHT XYLENE. Soap and water or diesel are best.
3) Drain all liquid from the pump. Do NOT allow liquid to freeze in the pump. Failure to do this will
result in damage to the internal components of the pump. In freezing conditions, draw some windshield
washer fluid or diesel into the pump to protect against freezing.
WARNINGS:
Always unplug unit before attempting to service.
Never spray flammable material.
Do NOT operate near flammable materials.
Use only original manufacturer parts.
Do NOT modify from original specifications.
Replace damaged hoses immediately.
Always wear protective clothing and
eye wear when operating.
Release pressure before disconnecting
spray control gun and spray wand.
Disconnect or unplug unit when not in use.
Never immerse pump.
!
!
Pump will not start:
• Check the circuit breaker
• Check for proper voltage (+/-10%)
& good electrical connections
• Check pressure switch for proper
operation
• Check motor for an open or grounded
circuit
• Check for a locked drive assembly
Leaks from pump head or switch:
• Check for loose screws at the switch
or pump head
• Switch diaphragm may be torn or pinched
Noisy or Rough Operation:
• Check for loose upper housing or drive
screws
• Is the surface that the pump is sitting on
magnifying the normal noise
Pump will not shut off:
• If recirculator is installed it will need to be
adjusted to 175psi for the pressure
switch to operate
• Check that the outlet hose is closed
an does not leak
• Check for trapped air in the head or
outlet hose
• Check for proper operating voltage
(+/-10%) to pump
• Check valve assembly for wear
• Check for loose drive assembly or
upper housing screws
• Check pressure switch to verify it has not
moved out of adjustment
Pump will not prime:
• Out of product
• Check for debris in strainer
• Check for vacuum leak in suction hose
• Check suction tube and outlet hose for
kinks or clogs
• Check for debris in valve plate
• Check for proper operating voltage
(+/-10%) with the pump operating
• Check upper housing for cracks
• Be sure spray control handle and spray
tip are open and free of debris
• If pump has been sitting try turning the
unit upside down and pour water into the
suction hose or attach a garden hose to
the suction hose and turn the garden hose
on. Then turn the unit on. This procedure
will force water thru the valves and free
them if they are sticking.
If you have any questions regarding the use or repair of this product
please feel free to contact Customer Support by telephone:
800.801.7832 – 847.639.7272 or via email: support@4progressive.com.
PN:01088