Clearance: Dimension Measured From:
A: Rise 1” minimum Finished Floor
B: Sidewall 7-1/2” Side of Unit
C: Ceiling 30” Top of Unit
D: Alcove Width 48” Sidewall to Sidewall (Minimum)
E: Alcove Depth 36” Front to back wall (Maximum)
Clearance Requirements
Regency P33 Sunrise Gas Fireplace
Model P33S-NG4 P33S-LP4
Fuel Type Natural Gas Propane
Minimum Supply Pressure 5” W.C. (1.25 kPa) 11” W.C. (2.73 kPa)
Manifold Pressure - High 3.5” W.C. (0.87 kPa) 10” W.C. (2.49 kPa)
Manifold Pressure - Low 1.6” W.C. (0.39 kPa) 6.4” W.C. (1.59 kPa)
Maximum Input
Altitude 0-4500 ft. (0-1372m)
17,000 BTU/h
(4.98 kW)
15,500 BTU/h
(4.54 kW)
Vent Sizing 4” Inner / 6 5/8” Outer 4” Inner / 6 5/8” Outer
Unit Dimensions Description P33S
A Front Face Width 33-5/8” (846mm)
B Rear Firebox Width 23” (584mm)
C Front Face Height 29” (737mm)
D Height w/ Standoff 31 1/2” (800mm)
E Unit Depth 12-3/4” (324mm)
F Firebox Height 29” (737mm)
Framing Dimensions Description P33S
G Framing Width 33-1/4” (845mm)
H** Framing Height** 31-3/4” (806mm)**
I*
Framing Rise from Floor
1” (25mm) minimum*
J
Framing
Depth
Vertical
19 -1/2” (495mm) Vertical Rise
16 1/2” (419mm) Rigid 12-3/4” (324mm) Flex
Horizontal
K Corner Wall Length 37 -1/2” (953mm)
L Corner Facing Wall Width 53-1/4” (1353mm)
M*** Framed Chase Ceiling*** 36” (914mm) Rigid*** 32” (813mm) Flex***
N Vent Centerline Height 30” (762mm) Rigid 26” (660mm) Flex
Dimension Description P33S
O Gas Connection Height 1-1/2” (38mm)
P Gas Connection Inset 4” (102mm)
Q Gas Connection Width 3” (76mm)
R Minimum Framing Depth 16 1/2” (419mm) Rigid / 12-3/4” (324mm) Flex
S
Maximum Framing Depth
(including wall thickness)
40 1/2” (1028mm) Rigid / 36-3/4” (933mm) Flex
P33 Sunrise Gas Fireplace
Approved Venting Systems
Flex Vent Systems: FPI AstroCap™ Flex Vent
Rigid Pipe Vent Systems: Simpson Direct Vent Pro®
American Metal Products® Amerivent Direct
Security Secure Vent®
Selkirk Direct-Temp™
Metal-Fab® Sure Seal
* The unit must be raised a minimum of 1” above the nished oor.
** Dimension H = H + I (minimum)
*** Dimension M = M + I (minimum)
This manual is intended to be a Sales Reference Guide only.
Do NOT use for actual framing and installation of any unit.
Some speci cations may change without notice.
You must use the actual manual for exact installation speci cations.
WARNING
Failure to maintain required clearances is a major cause of chimney related res.
Installation of this replace must comply with these clearances
Please note: Due to ongoing product development, product appearance and speci cations
are subject to change without notice.
B
C
Close to Ceiling
Regency P33 Sunrise Gas Fireplace