0 10 20 30 40 50 60 70 80
1.0
1.5
2.0
2.5
3.0
3.5
Load: 3 watt
Initial
0
23
Cell Type CR14500
Specifications
Typical Characteristics
1650mAh
3V
10mA
1500mA
3500mA
-40 60
17g
D14mm
H50mm
d6.3mm
Dimensions
Nominal Capacity
*1
Nominal Voltage
Standard Discharge Current
Weight
Max. Discharge Current
Temperature Range
Continuous
*2
Pulse
*3
Nominal capacity is determined to an end voltage of 2.0V when the battery is
allowed to discharge at a standard current level at 23
o
C.
*1
Current value is determined to be the level at which 50% of the nominal
capacity is obtained with an end voltage of 2.0V at 23
o
C.
*2
Current value for obtaining 1.0V cell voltage when pulse is applied for
15seconds at 50% discharge depth at 23
o
C.
*3
Discharge Characteristics of CR14500
Cell Voltage(V)
Duration (minute)
Cell Voltage(V)
Number of Cycles
Discharge Characteristics of CR14500
Pulse Discharge Characteristics of CR14500
Cell Voltage(V)
Duration(hour)
H
D
d
Discharge Characteristics of CR14500
Cell Voltage(V)
Duration(hour)
0 10 20 30 40 50 60 70 80
1.0
1.5
2.0
2.5
3.0
3.5
Load: 100ohm
Initial
-20
23
60
0 20 40 60 80 100 120 140 160
1.0
1.5
2.0
2.5
3.0
3.5
Load: 200ohm
In itia l
-20
23
60
0 200 400 600 800 1000 1200 1400 1600 1800
1.0
1.5
2.0
2.5
3.0
3.5
1.2A 3s on / 7s off
Initial
-20
23