Sanyo HR-4/3FAUC Battery Charger User Manual


 
Size : 4/3FA
3700mAh
3300mAh
1.2V
Fast Charge
2)
3000 mA x about 1.5h
Charge
Condition
Fast Charge
2)
0°C - 40°C
0°C - 50°C
Less than
30days
-20°C - 50°C
Less than
90days
-20°C - 40°C
Less than
1year
-20°C - 30°C
About 62 g
18.0(D) x 67.5(H) mm
4)With tube.
T
y
pical Characteristics
Charge Discharge
1)Single cell capacity under the following condition.
Dimensions
(with tube)
Specifications
Cell T
y
pe HR-4/3FAUC
Charge : 370mA×16h, Discharge : 740mA(E.V.=1.0V) at 20°C
Nominal Voltage
Discharge Condition
Weight
4)
Size
4)
:(Diameter) x (Height)
Type : Nickel-Metal Hydride Battery
Internal Impedance
3)
(after discharge to E.V.=1.0V)
Charging Current x Time
D
H
18.0 mm
67.5 mm
2)Use recommended charging system.
3)After a few charge and discharge cycles under the above 1) condition.
67.5 mm
Ambient Temp.
Storage
Condition
18.0 mm
Capacity
1)
Typical
Minimum
0.9
1.0
1.1
1.2
1.3
1.4
1.5
1.6
0 1000 2000 3000 4000 5000
Discharge Capacity (mAh)
Cell Voltage (V)
Charge : 400mA x 16h
Rest : 1h
Discharge : 800mA, 2000mA, 4000mA (E.V.=1.0V)
Ambient Temp. : 20°C
800mA
2000m 4000mA
1.0
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
0 102030405060708090
Charge Time (min)
Cell Voltage (V)
Charge : 3000mA (-V=10mV)
Ambient Temp. : 0°C,20°C,40°C
0°C
20°C
40°C
About 18m(at 1000Hz)