Sanyo HR-4/5AUC Battery Charger User Manual


 
Size : 4/5AUC
1700mAh
1550mAh
1.2V
Fast Charge
2)
1700 mA x about 1.1h
Charge
Condition
Fast Charge
2)
0°C - 40°C
0°C - 50°C
Less than
30days
-20°C - 50°C
Less than
90days
-20°C - 40°C
Less than
1year
-20°C - 30°C
About 35 g
17.0(D) x 43.0(H) mm
T
y
pical Characteristics
Charge Discharge
43.0 mm
Ambient Temp.
Storage
Condition
17.0 mm
Capacity
1)
Typical
Minimum
Charging Current x Time
D
H
17.0 mm
43.0 mm
2)Use recommended charging system.
4)With tube.
3)After a few charge and discharge cycles under the above 1) condition.
1)Single cell capacity under the following condition.
Dimensions
(with tube)
Specifications
Cell T
y
pe HR-4/5AUC
Charge : 170mA×16h, Discharge : 340mA(E.V.=1.0V) at 20°C
Nominal Voltage
Discharge Condition
Weight
4)
Size
4)
:(Diameter) x (Height)
Type : Nickel-Metal Hydride Battery
Internal Impedance
3)
(after discharge to E.V.=1.0V)
0.9
1.0
1.1
1.2
1.3
1.4
1.5
1.6
0 200 400 600 800 1000 1200 1400 1600 1800
Discharge Capacity (mAh)
Cell Voltage (V)
Charge : 170mA x 16h
Rest : 1h
Discharge : 340mA, 1700mA, 3400mA (E.V.=1.0V)
Ambient Temp. : 20°C
340mA
1700mA
3400mA
1.0
1.1
1.2
1.3
1.4
1.5
1.6
1.7
1.8
0 1020304050607080
Charge Time (min)
Cell Voltage (V)
Charge : 1700mA (-V=10mV)
Ambient Temp. : 0°C,20°C,40°C
0°C
20°C
40°C
A
bout 20m
(
at 1000Hz
)