Bostitch BTFP02006 Air Compressor User Manual


 
12
 
will accept the plug on the product
 
 
 

Risk of Property Damage. The use of an undersized extension cord will cause
voltage to drop resulting in power loss to the motor and overheating. Instead of using an exten-
sion cord, increase the working reach of the air hose by attaching another length of hose to its
end. Attach additional lengths of hose as needed.
VOLTAGE AND CIRCUIT PROTECTION
Refer to the Voltage and Minimum Branch Circuit Requirements under Specifications.
Certain air compressors can be operated on a 15 amp circuit if the following
conditions are met.
 • VoltagesupplytocircuitmustcomplywiththeNationalElectricalCode.
 • Circuitisnotusedtosupplyanyotherelectricalneeds.
• Extensioncordscomplywithspecifications.
 • Circuit isequipped witha 15Amp circuitbreaker or15 Amp timedelay fuse.NOTE: If
compressorisconnectedtoacircuitprotectedbyfuses,useonlytimedelayfuses.Timedelay
fusesshouldbemarked“D”inCanadaand“T”intheUS.
If any of the above conditions cannot be met, or if operation of the compressor repeatedly
causes interruption of the power, it may be necessary to operate it from a 20 amp circuit. It is
not necessary to change the cord set.
COMPATIBILITY
Air tools and accessories that are run off the compressor must be compatible with petroleum-
based products. If you suspect that a material is not compatible with petroleum products, an
air line filter for removal of moisture and oil vapor in compressed air is required.
NOTE: Always use an air line filter to remove moisture and oil vapor when spraying paint.
LOCATION
Place the air compressor in a clean, dry and well ventilated area at least 12" (30.5 cm) away from

from areas that have dirt and/or volatile fumes in the atmosphere. These impurities may clog the
intake filter and valves, causing inefficient operation.
The air compressor pump and shroud are designed to allow for proper cooling.
The ventilation openings on the compressor are necessary to maintain proper operating
temperature. Do not place rags or other containers on or near these openings.
Place the air compressor on a flat surface resting on the rubber feet and wheels.
PREPARATION FOR USE
PRE-START CHECKLIST (FIG. 1)
1
2.
Plug the power cord into the correct branch circuit receptacle.
See Voltage and Circuit
Protection under Installation.

Draining
Air
Tank
under
Maintenance
.

       
Checking Safety Valve
under
Maintenance.
6. Check pump oil level, see
Compressor Pump Oil
under
Maintenance
.
Do not operate without oil or with inadequate oil. Bostitch is not responsible
for compressor failure caused by inadequate oil.