shutting off when in use.

Asked by reseekp on 01/15/2008 9  Answers

ManualsOnline posted an answer 16 years, 9 months ago

The ManualsOnline team has found the manual for this product! We hope it helps solve your problem. Get the Manual Here
5 It's a gasket, I fixed it temporarly with a piece from a rubber glove. Does anyone know were to buy the replacement gasket?
Was this answer helpful?
4 I tried to download the manual but couldn't. Would you please replace the link for it? Thanks, Wes
Was this answer helpful?
3 alinbuckeye, Not 100% sure yet, but might have fixed my 47065 compressor. At first, I thought maybe the motor was overloading or getting too hot, but it didn't seem to be. So, I decided to try to unplug the breaker/overload switch on the side of the compressor. When I pulled on the two wires slightly, the wires pulled out from the spade terminal connectors (seems like they were not crimped on very good). I then noticed the spade connectors were soldered to the overload switch. So, I used a small screwdriver to pry open the ends of the spade terminal connectors and re-crimped the wires back into those ends. Now, when I run the compressor, it does not shut off. Could it have been poor connections to the overload switch? I am not 100% sure yet, but I ran it for about 20-30 minutes this morning, with no shut-off problems. Before, it would randomly shut off within a few minutes, time after time. I will post another message, if it starts acting up again.
Was this answer helpful?
3 I have a problem with the Central Pneumatic compressor # 47065 overheating when it is filling the tank. It has gotten so hot that it has melted the plastic muffler. I have checked and re-checked the oil level. All is correct. I have taken the piston apart but I don't know what to look for any way. Does anyone have any suggestions? The compressor is about 4 years old and worked for a couple of years.
Was this answer helpful?
3 Good Luck, I hope this helps CSM Robbibaro USA (ret) I found this manual. 47065 AC manual.pdf
Was this answer helpful?
3 I have a constant leak of air coming out under the on off switch, under the plastic shroud that states do not remove,takes forever to pump up. How can i get a replacement air outlet valve.
Was this answer helpful?
1 I also have a problem with 47065 air compressor, which is shutting off when in use. I can press the reset switch and it runs again for a little while (and then shuts off again). Any suggestions?
Was this answer helpful?
1 Did you find the answer to the compressor's problem. I have the same issue with mine.
Was this answer helpful?
0 At first, my compressor would not turn off. Unpluged the unit, turned back on and still the same problem. The end result: one of the wires leading into the on/off compartment overlooaded and cause a small fire!!!!! Be very careful and look behind the compartment and smell. This is the problem. Im trying to find a replacement part. If anyone knows, please help. Thanks. Robbie F.
Was this answer helpful?