
Electrical Requirements
Wire Size
Sample Nameplate
120524
COOLING EQUIPMENT
FOLLOWING ITEMS
OUTDOOR GRILLE
INDOOR GRILLE
S
A
M
P
L
E
Electrical Rating Table
41
A51
21
A02
01
A03
Use ONLY wire size recommended for
single outlet branch circuit.
Use ONLY type and size fuse or HACR
circuit breaker indicated on unit’s rating
plate (See sample below). Proper over
current protection to the units is the respon-
sibility of the owner.
Unit MUST be grounded from branch circuit
to unit, or through separate ground wire
provided on permanently connected units.
Be sure that branch circuit or general
purpose outlet is grounded.
Use recommended wire size given in tables
and install a single branch circuit. All wiring
must comply with local and national codes.
NOTE: Use copper conductors only.
NOTE: All field wiring must comply with NEC and local
codes. It is the responsability of the installer to insure that
the electrical codes are met.
NOTE: Use copper conductors ONLY. Wire sizes are per
NEC. Check local codes for overseas applications.
AWG --- American Wire Gauge
* Single circuit from main box.
** Based on 100’ or less of copper, single insulated
conductor at 60° C
Recommended branch circuit wire sizes*
Nameplate maximum circuit breaker size AWG Wire size**
Electrical shock hazard.
WARNING
Turn OFF electric power before service
or intallation.
Unit must be properly grounded.
Unit must have correct fuse or circuit
breaker protection.
Unit’s supply circuit must have the
correct wire conductor size.
All electrical connections and wiring must
be installed by a qualified electrician and
conform to the National Electrical Code
and all local codes which have jurisdiction.
Failure to do so can result in property
damage, personal injury and/or death.
3
Heater Watts 2500/2050 3400/2780 5000/4090 2500/2050 3400/2780 5000/4090 2500/2050 3400/2780 5000/4090
Voltage
Heating BTU/h 8500/7000 11600/9500 17000/13900 8500/7000 11600/9500 17000/13900 8500/7000 11600/9500 17000/13900
Heating Current (Amps) 10.9/9.9 14.8/13.4 21.7/19.7 10.9/9.9 14.8/13.4 21.7/19.7 10.9/9.9 14.8/13.4 21.7/19.7
Minimum Circuit Ampacity 15 19.9 28.6 15 19.9 28.6 15 19.9 28.6
Branch Circuit Fuse (Amps) 15 20 30 15 20 30 15 20 3
0
LRA - Compressor (Amps) 18.5 18.5 18.5 26 26 26 42 42 42
Cooling Current (Amps) 4.1/4.3 4.1/4.3 4.1/4.3 5.3/5.5 5.3/5.5 5.3/5.5 8.2/8.6 8.2/8.6 8.2/8.6
Basic heater Size 2.5 Kw 3.4 Kw 5.0 Kw 2.5 Kw 3.4 Kw 5.0 Kw 2.5 Kw 3.4 Kw 5.0 Kw
Power Connection
230/208 230/208 208/230
HARD WIRED HARD WIRED HARD WIRED
Electrical Data
Recommended Branch
Circuit Wire Sizes
* AWG-American Wire Gauge
14 12 10 14 1012 14 12 10