—3—
1. PREFACE
This service manual provides various service information, including the mechanical and electrical parts, etc.
This room air conditioner was manufactured and assembled under a strict quality control system.
The refrigerant is charged at the factory. Be sure to read the safety precautions prior to servicing the unit.
1.1 FEATURES
• DESIGNED FOR COOLING ONLY
• POWERFUL AND INCREDIBLE COOLING
• TOP-DOWN CHASSIS FOR THE SIMPLE INSTALLATION AND SERVICE
• BUILT-IN ADJUSTABLE THERMOSTAT
• WASHABLE ONE-TOUCH FILTER
• COMPACT SIZE
1.2 SPECIFICATIONS
MODELS
ITEMS
COOLING CAPACITY (BTU/h) 5,250 7,000
POWER SUPPLY (Phase, V, Hz) 1ø, 115V, 60HZ
INPUT (W) 540 720
OPERATING CURRENT (AMP.) 5.0 6.7
REFRIGERANT CONTROL CAPILLARY TUBE
REFRIGERANT CHARGE (R-22) 221g (7.8 oz) 315g (11.1 oz)
INSIDE FAN TURBO FAN
OUTSIDE FAN PROPELLER FAN WITH SLINGER RING
AIR DISCHARGE 2-WAY (RIGHT AND LEFT)
CHASSIS TOP-DOWN
PROTECTOR
TEMPERATURE CONTROL THERMOSTAT
ROTARY SWITCH
FAN MOTOR 6 POLES, 16W 6 POLES, 27W
• OVERLOAD PROTECTOR FOR COMPRESSOR
• INTERNAL PROTECTOR FOR FAN MOTOR
5 STEP (LOW FAN, HIGH FAN, OFF, HIGH COOL, LOW COOL)
ZQ05A10B ZQ07A10B