AKG Acoustics CU700 Battery Charger User Manual


 
6
Charging Cycle
9
Table 2: Charging cycle
The charging cycle will start automatically as soon as you insert a transmitter with rechargeable bat-
teries into the charger.
1. Disconnect the DC cable from the rear panel DC 12 V jack.
2. Use a cloth moistened (not wet!) with water to clean the surfaces of the charger.
Never use caustic or scouring cleaners or cleaning agents containing alcohol or solvents
since these may damage the enamel or plastic parts.
CU
700
STATUS LED STATUS
orange The voltage and temperature of the batteries are being checked.
red The batteries are being charged.
Charging time is approx. 1.5 hours for completely discharged bat-
teries and proportionately less for partially discharged batteries.
green The batteries are fully charged; the charging cycle is completed.
The charger has switched to trickle charging mode.
You may remove the transmitter from the charger.
Due to the charging process, the batteries may heat up to +60°C.
This is normal.
CU
700
7
Cleaning
NOTICE
!