Allied Telesis AT-RPS3204 Welding System User Manual


 
4 5 6
13. Verify that the On/Off switches for the power supplies marked A1 and A2 are
in the Off (out) position.
14. Position the power cord retaining clip in the up position.
15. Plug the power cord into the AC power connector on the back of the power
supply.
16. Secure the cord by lowering the power cord retaining clip.
17. Plug the AC power cord into an AC wall outlet rated for at least 10 Amps.
18. Verify that the On/Off switches for the power supplies marked B1 and B2 are
in the Off (out) position.
19. Repeat steps 13 through 17 to plug in the other power cord.
Note
DO NOT plug the second power cord into the outlet where the first power
cord is plugged in unless the outlet is rated for at least 20 Amps.
20. Plug one end of the 21-pin D-combo connector cable into the connector
labeled “RPS INPUT” on the rear panel of a switch.
For information about the pinouts for the 21-pin D-combo connector cable,
see Appendix A of the switch’s installation guide.
21. Tighten the thumb screws on the connector.
22. Plug the other end of the cable into the connector labeled “RPS OUTPUT
A1” on the back of the RPS3204 unit.
23. Tighten the thumb screws on the connector.
Note
An AT-PWR3202 Power Supply is NOT hot-swappable into and out of the
AT-RPS3204 Redundant Power Supply. To replace an AT-PWR3202 unit,
first turn the power off using the appropriate On/Off switch and then remove
and replace the power supply.
To remove the connector cable, turn the power off first using the
appropriate On/Off switch.
24. Press the On/Off switch for the power supply marked A1 to move it to the On
(in) position.
The RPS LED on the front of the switch should be green. For more
information about the RPS LED, refer to the switch’s installation guide.
To install and connect additional AT-PWR3202 Power Supplies, refer to the
documentation that is shipped with that product.
Specifications
Electrical, Safety, and Emissions Statements
This product meets the following standards:
RFI Emissions EN 55022 Class A, EN61000-3-2, EN61000-3-3,
VCCI Class A
Immunity EN 55024
Electrical Safety UL 60950 (
C
UL
US
), EN 60950 (TUV)
Copyright © 2008 Allied Telesis, Inc. All rights reserved. No part of this publication may be
reproduced without prior written permission from Allied Telesis, Inc. www.alliedtelesis.com.
194
RPS OUTPUT A1
12V
DC
O
N
O
FF
A1
P
S OUTPUT
A2
12VDC
RPS OUTPU
T A1
12VDC
AC INPUT A2/A1
100 - 240 VAC
~
ON
OFF
A1
P
S OUTPUT A2
12VDC
RPS OUTPU
T A1
12VDC
AC INPUT A2/A1
100 - 240 VAC
~
ON
O
FF
A1
P
S OUTPUT A2
12VDC
RPS OUTPUT A1
12VD
C
AC INPUT A2/A1
100 - 240 VAC
~
O
N
O
F
F
A1
RPS INPUT
400
RPS INPUT
401
RPS OUTPUT A2
12VDC
RPS OUTPUT A1
12VDC
AC INPUT A2/A1
100 - 240 VAC
~
ON
OFF
A1
A2
199
RPS OUTPUT A2
12VDC
RPS OUTPUT A1
12VD
C
AC INPUT A2/A1
100 - 240
VA
C
~
ON
OFF
ON
OFF
A1
A2
Item Specification
Dimensions (H x W x D) 43.7 x 440.5 x 360.6 mm (1.72 x 17.34 x 14.20
in.)
Operating Temperature 0° C to 40° C
Relative Humidity <85% noncondensing
Supply Voltage 12 V
RPS Input Voltage 100 - 240 V AC
RPS Output Voltage 12 V DC
U.S. Federal Communications Commission
Radiated Energy
Note: This equipment has been tested and found to comply with the limits for a Class A digital device
pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance
with this instruction manual, may cause harmful interference to radio communications. Operation of
this equipment in a residential area is likely to cause harmful interference in which case the user will
be required to correct the interference at his own expense.
Note: Modifications or changes not expressly approved of by the manufacturer or the FCC, can void
your right to operate this equipment.
Industry Canada
This Class A digital apparatus meets all requirements of the Canadian Interference-Causing
Equipment Regulations.
Cet appareil numérique de la classe A respecte toutes les exigences du Règlement sur le matériel
brouilleur du Canada.
Warning: In a domestic environment this product may cause radio
interference in which case the use may be required to take adequate
measures.
RPS OUTPUT A2
12VDC
RPS OUTPUT A1
12VDC
AC INPUT A2/A1
100 - 240
VAC
~
ON
OFF
ON
OFF
A1
A2