Anton/Bauer ElipZ 10K Battery Charger User Manual


 
World Headquarters 14 Progress Drive, Shelton, CT U.S.A. Tel (203) 929-1100 support@antonbauer.com
Europe
Eurode Business Center, Eurode-Park1, 6461KB Kerkrade, The Netherlands Tel +31 45-563-9220
eurosupport@antonbauer.com
Singapore Office
-Anton/Bauer 6 New Industrial Road, #02-02 Hoe Huat Ind. Bld., Singapore 536199 (65)2975784 Fax (65) 2825235
www.antonbauer.com
7595-0303 Rev J
Charging Batter
y
(1) Remove ELIPZ cable from battery if attached to camera.
(2) Remove battery from camera.
(3) Attach charger to AC mains source (100-240 VAC 50-60 Hz). Blue LED should light on charger (If blue LED does not
light, check mains source).
(4) Attach ELIPZ connector from charger to battery.
(5) Red light on charger will begin to flash within 10 seconds. This means the battery is charging.
(6) Red light will go out (approximately 4 hours) and Green LED will flash. Battery is now at least 80% full.
(7) Green LED will glow steadily (approximately 6 hours) when battery has completed full charge cycle.
Note: If battery is not removed from charger for longer than 1 week, charger will automatically re-initiate charge program.
CAUTION: DO NOT OBSTRUCT VENTILATION TO CHARGER. DO NOT COVER DURING OPERATION.
The charger power supply cord plug and appliance coupler are relied upon as the disconnect devices and shall remain readily
accessible.
ELIPZ Charger specifications
Electrical:
Rated Input voltage: 100-240VAC
Rated Power: 30 watts
Line Input Frequency: 50-60Hz
Output Voltage: 8.4V
Output Current: 2.3A
Environmental:
Operating Temperature Range: 0ºC to 40ºC
Storage Temperature Range: -20ºC to 60ºC
Humidity: <80% relative humidity
Physical:
Size: Approximately 5.42 L x 3.10 W x 2.17 H
Weight: .85 lbs (385 grams)