Page 26
Chapter 5: Advanced Commands
Figure 5-2. Current configured parameters list.
To reset to factory default, setting the IP mode to autoip and removing any
overrides, type in:
reset_to_default.sh
To change the baud rate of the serial extension interface, type in:
stty X –F /dev/ttyS0
(replace X with desired baud rate)
To disable/enable the link for a specific device, type in:
ast_send_event -1 e_stop_link
ast_send_event -1 e_reconnect
5.1 Advanced IP Commands
Each device has three possible modes of establishing an IP address: autoip, dhcp,
and static.
1. AutoIP is the default mode and it will always automatically assign available IP
addresses in the private IP domain 169.254.xxx.xxx
NOTE: The MediaCento IPX uses the Avahi zeroconf protocol to find an available IP
in the 169.254.xxx.xxx range.