Black & Decker BDBN1202 Nail Gun User Manual


 
10
For assistance with your product, visit our website www.blackanddecker.com for the
location of the service center nearest you or call the BLACK & DECKER help line at
1-800-544-6986.
Problem
• LED status indicator is
flashing red.
• LED status indicator is
staying on RED .
• Nail will not fire.
• Unit will not start.
• Battery pack will not
charge.
Possible Cause
• Nail jammed in the
nosepiece.
• Battery is low or out of
power.
• Contact trip is not fully
depressed.
• Battery pack not
installed properly.
• Battery pack not
charged.
• Battery pack not
inserted into charger.
• Charger not plugged in.
• Surrounding air
temperature too hot or too
cold.
Solution
• Engage lock off. Disconnect
battery. Release pusher from
behind nails. See page 9.
• Recharge battery.
• Depress the contact trip
firmly against the work
surface. Depress and
maintain pressure on the
trigger.
• Check battery pack installation.
• Check battery pack charging
requirements.
• Insert battery pack into charger
until red LED appears.
• Plug charger into a working outlet.
Refer to “Important Charging Notes”
for more details.
• Move charger and battery pack
to a surrounding air temperature
of above 40 degree F(4,5°C) or
below 105 degree F (+40,5°C).