Campbell Hausfeld HU3501 Air Compressor User Manual


 
Gauge of Cord 16 14 10
Extension cords for 120V/10 Amp Unit
Length of Cord (ft) 25 50 100
HU3501
3
Assembly
ASSEMBLY TOOLS REQUIRED
Tools (not provided) for assembly:
- 2 14mm wrench or socket wrench
- 2 17mm wrench or socket wrench
FOOT ASSEMBLY (FIGURE 1)
Foot assembly kit includes:
- 1 rubber foot
- 1 bolt
- 2 washers
- 1 nut
WHEEL ASSEMBLY (FIGURE 2)
Wheel assembly kit includes:
- 2 wheels*
- 2 axle bolts*
- 2 lock washers*
- 2 nuts*
The items marked with an asterisk (*)
were shipped loose with the unit.
1. Wheel has an offset hub. With offset
hub facing axle iron, assemble axle bolt
through holes in wheel and axle iron.
2. Place lock washer on axle bolt. Then
tighten nut securely to threaded
part of axle bolt.
3. Repeat procedure with other side.
HANDLE ASSEMBLY (FIGURE 3)
Never use the
handle to lift the
unit completely off the ground. Only
use the handle to lift one end so the
wheels may be used to move the unit.
Handle assembly kit includes:
- 1 handle
- 2 bolts
1. Insert ends of handle into tube
shaped brackets on tank.
2. Align screw holes.
3. Thread screw into hole until tight.
Installation
LOCATION
It is extremely important to install the
compressor in a clean, well ventilated area
where the surrounding air temperature
will not be more than 100°F.
A minimum clearance of 18 inches between
the compressor and a wall is required
because objects could obstruct air flow.
Do not locate the
compressor air inlet
near steam, paint spray, sandblast areas
or any other source of contamination. This
debris will damage the motor
Household use only. Store indoors.
ELECTRICAL INSTALLATION
1. Check and tighten all bolts, fittings,
etc., before operating compressor.
2. Operate compressor in a ventilated
area so that compressor may be
properly cooled.
3. Compressor should be located where
it can be directly plugged into an
outlet, but if this is not possible, an
extension cord may be used. It should
be selected using the extension cord
chart on page 3 as a guide.
4. To avoid loss of power and
overheating, it is better to use
additional air hose instead of
extension cords to reach work area.
WIRING
1. Local electrical wiring codes
differ from area to area. Source
wiring, plug and protector must
be rated for at least the amperage
and voltage indicated on motor
nameplate, and meet all electrical
codes for this minimum .
2. Use a slow blow fuse type T or a
circuit breaker.
Overheating, short
circuiting and fire
damage will result from inadequate
wiring, etc.
All wiring and
electrical
connections should be performed by a
qualified electrician. Installation must
be in accordance with local codes and
national electrical codes.
NOTE: 120 volt, compressor can be
operated on a 120 volt, 15 amp circuit
under the following conditions:
a. No other electrical appliances or
lights are connected to the same
branch circuit.
b. Voltage supply is normal.
c. Extension cords are of the
minimum gauge specified in this
instruction manual.
d. Circuit is equipped with a 15 amp
circuit breaker or a 15 amp slow
blow fuse type T.
3. If above conditions cannot be met
or if nuisance tripping of current
protection device occurs, it may be
necessary to operate compressor
from a 120 volt, 20 amp circuit.
Power cord White Line No
Motor cord White Load No
Power cord Black Line Yes
Motor cord Black Load Yes
Wire and Terminal Guide
Wire Color Terminal Hot
() When the unit is not in operation
www.chpower.com
Wheel
Axle Bolt
Lock
Washer
Nut
Figure 2 - Wheel assembly
Bolt
Handle
Tank
Figure 3 - Handle Assembly
Rubber Foot
Washer
Bolt
Washer
Nut
Figure 1 - Rubber foot installation