Campbell Hausfeld PS250B Paint Sprayer User Manual


 
11
Operating Instructions and Assembly Instructions
Airless Paint Sprayers
CLEANUP FOR CHANGING PAINTS
OR TEMPORARY STORAGE FOR
MORE THAN ONE NIGHT
WEAR ALL NECESSARY
SAFETY GEAR
NECESSARY TOOLS / MATERIALS:
• Pliers
• Rag
• Gloves
• Two (2) buckets
• At least one (1) gallon of cleaning
fluid
• Cleaning brush
NOTE: Do NOT disconnect any hoses.
NOTE: Refer to coating manufacturer
for recommended cleaning fluid.
1. Turn prime/spray control to PRIME
position.
2. Turn power switch to ON.
High pressure
hose may still be
pressurized with prime/spray control
in the PRIME position. With the gun
pointed in a safe direction, pull the
gun trigger to relieve any pressure in
the hose.
3. Turn pressure to HIGH (completely
clockwise).
4. Tilt unit back, lift suction assembly
above fluid level in bucket.
While holding suction assembly
above paint level, allow pump to
run until empty.
5. Immediately place both suction
assembly and bypass tube in a
bucket containing enough cleaning
fluid to cover suction bell by two
inches. Allow pump to prime and
begin circulating fluid.
6. While fluid is circulating, soak rag
in fluid and wipe exterior of suction
assembly and bypass tube. Remove
suction filter with pliers. Wipe
inside of suction filter housing with
rag removing excess paint buildup.
Clean both sides of suction filter
with rag and reinsert filter into
suction filter housing.
NOTE: Do NOT allow fluid to circulate
for more than 15 minutes.
Cleaning Pump
Turn Pressure to HIGH
(completely clockwise)
3
4
Lift Suction Assembly above
Paint Level in Bucket
www.chpower.com
Turn Prime/Spray
Control to PRIME
Position
1
6
Wipe Exterior of Suction
Assembly and Bypass Tube
Suction Assembly and
Bypass Tube in Bucket
of cleaning fluid
11
2
Turn power switch to ON
(shown in the OFF position)
5