Central Pneumatic Air Compressor 93909 Nail Gun User Manual


 
SKU 97511
93909 For Technical Questions, Please Call 1-800-444-3353 Page 7
OPERATION
NOTE: For additional references to the parts listed below, refer to the Assembly
Diagram on page 11.
1. Adjust the Exhaust Cover (4) to direct exhaust as desired.
2. To re a nail, place the nose of the Nailer on the workpiece. The Nailer should
not re if the Safety (38) is not depressed. Once the Safety is depressed,
gently and briey squeeze the Trigger once to re one nail. Release
the Trigger. Do not re repeatedly; nails could bounce off on one another,
damaging the workpiece or causing personal injury.
3. With the nose of the Nailer on the workpiece, squeeze the Trigger again to
re another nail. Continue ring nails as needed.
4. When the work is completed, disconnect the air supply and remove the nails from
the nailer.
3. Orient a strip of nails with the points down, and drop the strip of nails into the
Magazine (71). (See Figure C.)
4. Slide the strip of nails forward in the Magazine (71). NOTE: The Magazine will
hold 60, 10 gauge nails. (See Figure C.)
5. Unlatch the Feeder Shoe (52), and allow the Feeder Shoe to slide forward against
the strip of nails. (See Figure C.)
Loading Nails (continued)