Cooper Lighting IMI-6950 Work Light User Manual


 
LUMINAIRE RE-INSTALLATION:
1. Note: Install lens to housing if removed during drilling. Reverse Step 3.
2. Secure hanging hook into the rear hooks of quick mount plate
(Figure 3 & 4).
3. Make wiring connection while luminaire is being suspended from hanging
hook.
4. Push excess wires and connectors up into the junction box.
5. Lift up luminaire onto the (4) four hooks of quick mount plate while guiding
the wires through center access hole (Figure 3).
6. Push luminaire forward for engagement. When it reaches the full-engaged
position, a “CLICK” can be heard.
CAUTION: If full engagement is not reached, it is not yet rigidly installed.
EPL Envoy
Task Light Field Installation Kit
Sheet 2 of 3
4/7/08 IMI-695D
INSTALLATION INSTRUCTIONS
IMPORTANT : READ CAREFULLY BEFORE INSTALLING FIXTURE. RETAIN FOR FUTURE REFERENCE
Customer First Center 1121 Highway 74 South Peachtree City, GA 30269 770.486.4800 FAX 770.486.4801 ADH080775
These instructions do not claim to cover all details or variations in the equipment, procedure, or process described, nor to provide directions for meeting every possible contingency during installation,
operation or maintenance. When additional information is desired to satisfy a problem not covered sufficiently for user’s purpose, please contact your nearest representative.
NOTE: Specifications and dimensions subject to change without notice.
Figure 6
Figure 4
FRONT HOOKS
LUMINAIRE
HANGING HOOK
REAR HOOKS
QUICK MOUNT
PLATE
Figure 5
LATCH
#8-32
SCREW
RETAINER
CENTER ACCESS HOLE
THUMB
SCREW
UPPER
REFLECTOR