Cooper Lighting STS7A30SFM1XG Work Light User Manual


 
STREETWORKS Outdoor Lighting Solutions 175Cooper Lighting
SQUARE TAPERED STEEL POLES
Mounting Fixture No. & Accessories
Shaft
3
Wall Height Base Mounting Location Arm (Ground
Square Straight Steel Size Thickness (ft.) Type Finish & Type of Arms Lengths Lug)
ST S7 A 30 SFM 1 XG
Bolt Anchor
Base Circle Bolt Shaft Bolt Net. Max. Fixture
Mtg. Catalog
1, 2
Wall Square Dia. Proj. Size Dia. &. Wt. EPA (Sq. Ft.)
4
EPA (Sq. Ft.)
4
Load—Include
Height Number Thickness (In.) (In.) (In.) (In.) Length (In.) (Lbs.) At Pole Top 2' Above Pole Top Bracket (Lbs.)
MH S BC BP B AB 80 90 100 80 90 100
20 STS6A20SF .120 Consult your Cooper Lighting Representative
25 STS6A25SF .120 Consult your Cooper Lighting Representative
30 STS7A30SF .120 Consult your Cooper Lighting Representative
30 STS7D30SF .180 Consult your Cooper Lighting Representative
35 STS8A35SF .120 Consult your Cooper Lighting Representative
39 STS8A39SF .120 Consult your Cooper Lighting Representative
NOTES: 1 Catalog number includes pole with anchor bolts with double nuts (BEFORE INSTALLING ANCHOR BOLTS MAKE SURE PROPER ANCHOR BOLT TEMPLATE IS OBTAINED FROM COOPER LIGHTING HEADQUARTERS).
2 Tenon size or machining for rectangular arms must be specified. Hand hole is located 180° from single arm.
3 Shaft size, base plate, anchor bolts and projections may vary slightly—all dimensions nominal.
4 EPAs based on shaft properties with wind normal to flat. EPAs calculated using base wind velocity as indicated plus 30% gust factor.
MACHINING FOR RECTANGULAR ARMS [Add as suffix]
Designation Designation Designation Quantity
Letter & Number Letter & Number Letter & Number & Location
M1 E1 Z1 Single
M2 E2 Z2 2 @ 180°
M3 E3 Z3 3 @ 120°
M4 E4 Z4 4 @ 90°
M5 E5 Z5 2 @ 90°
NOTES: Refer to Fixture Drilling Options on page 160.
ACCESSORIES
A=1/2" tapped hub
1
B=3/4" tapped hub
1
C=Convenience outlet
2
G=Grounding lug (max. wire #8 AWG)
H=Additional hand hole and cover—
12" below pole top—90° from hand hole.
NOTES: 1 Location is 3' above base–90° from hand hole.
2 Outlet is located 4' above base and on same side of pole
as hand hole, unless specified otherwise. Receptacle not
included, provision only.
MOUNTING OPTIONS [Add as suffix]
Fixed Tenon Designation O.D. Length
Number (In.) (In.)
1 2 3/8 3 1/2
2 2 3/8 4
3 3 1/2 5
934
7/8''
2 13/16''
3/4'' dia.
hole
(2) 3/8"
dia. holes
3 7/8''
DRILLING PATTERN
Type “M” [RCL, Landau, Galleria and Vision] Type “E” [Concourse III] Type “Z” [Credenza and Cirrus]
3/4'' dia.
hole
(2) 5/8''
dia. holes
2 7/16''
2 5/16''
4 7/8''
O.D.
LENGTH
9/16" [14mm]
dia. hole (3)
4 7/8" [124mm]
4" [102mm]
2 7/16" [62mm]
ORDERING INFORMATION
SAMPLE NUMBER: STS7A30SFM1XG