Craftsman 919.16732 Air Compressor User Manual


 
13- ENG
A10819
Air Compressor Pump (not shown):
Compresses air into the air tank.
Working air is not available until the
compressor has raised the air tank
pressure above that required at the
air outlet.
Check Valve: When the air
compressor is operating, the check
valve is "open", allowing compressed
air to enter the air tank. When the
air compressor reaches "cut-out"
pressure, the check valve "closes",
allowing air pressure to remain inside
the air tank.
Pressure Release Valve: The
pressure release valve located on
the side of the pressure switch, is
designed to automatically release
compressed air from the compressor
head and the outlet tube when the
air compressor reaches "cut-out"
pressure or is shut off. The pressure
release valve allows the motor to
restart freely. When the motor stops
running, air will be heard escaping
from this valve for a few seconds.
No air should be heard leaking when
the motor is running or after the unit
reaches "cut-out" pressure.
Check Valve
Pressure
Release
Valve
Motor Overload Protector: The
motor has an automatic reset
thermal overload protector. If the
motor overheats for any reason, the
overload protector will shut off the
motor. The motor must be allowed
to cool down before restarting. The
compressor will automatically restart
after the motor cools.
How to Use Your Unit
How to Stop:
1. Set the On/Auto/Off lever to
"Off".
Before Starting
Break-in Procedure
Risk of Unsafe
Operation. Serious
damage may result if the following
break-in instructions are not
closely followed.
This procedure is required before the
air compressor is put into service and
when the check valve or a complete
compressor pump has been replaced.
1. Make sure the On/Auto/Off lever
is in the "Off" position.
NOTE: Pull coupler back until it clicks
to prevent air from escaping through
the quick connect.
2.
Plug the power cord into the
correct branch circuit receptacle.
(Refer to Voltage and Circuit
Protection paragraph in the
Installation section of this
manual.)
3. Open the drain valve (counter-
clockwise) fully to permit air to
escape and prevent air pressure
build up in the air tank during the
break-in period.
4. Move the On/Auto/Off lever
to "On/Auto" position. The
compressor will start.