Craftsman 919.167461 Air Compressor User Manual


 
9- ENG
D28071
GLOSSARY
Become familiar with these terms
before operating the unit.
CFM: Cubic feet per minute.
SCFM: Standard cubic feet per
minute; a unit of measure of air deliv-
ery.
PSIG: Pounds per square inch
gauge; a unit of measure of pressure.
Code Certification: Products that
bear one or more of the following
marks: UL, CUL, ETL, CETL, have
been evaluated by OSHA certified
independent safety laboratories and
meet the applicable Underwriters
Laboratories Standards for Safety.
Cut-In Pressure: While the motor is
off, air tank pressure drops as you
continue to use your accessory.
When the tank pressure drops to a
certain low level the motor will restart
automatically. The low pressure at
which the motor automatically
restarts is called "cut-in" pressure.
Cut-Out Pressure: When an air
compressor is turned on and begins
to run, air pressure in the air tank
begins to build. It builds to a certain
high pressure before the motor auto-
matically shuts off - protecting your
air tank from pressure higher than its
capacity. The high pressure at which
the motor shuts off is called "cut-out"
pressure.
Branch Circuit: Circuit carrying elec-
tricity from electrical panel to outlet.
ACCESSORIES
DUTY CYCLE
This unit is capable of powering the following Accessories. The accessories are
available through the current Power and Hand Tool Catalog or full-line Sears
stores.
Accessories
In Line Filter
Tire Air Chuck
Quick Connector Sets (various
sizes)
Air Pressure Regulators
Oil Fog Lubricators
Air Hose:1/4", 3/8" or 1/2" I.D. in
various lengths
Refer to the selection chart located
on the unit to select the tools this unit
is capable of powering.
This air compressor pump is capable
of running continuously. However, to
prolong the life of your air compres-
sor, it is recommended that a
50%-75% average duty cycle be
maintained; that is, the air compres-
sor pump should not run more than
30-45 minutes in any given hour.