Craftsman 919.724591 Air Compressor User Manual


 
9 - ENG
A14841
ACCESSORIES
This unit is capable of powering the following Accessories. The accessories are
available through the current Power and Hand Tool Catalog or full-line Sears
stores.
Accessories
• In Line Filter
Tire Air Chuck
Quick Connector Sets (various
sizes)
GLOSSARY
Become familiar with these terms
before operating the unit.
CFM: Cubic feet per minute.
SCFM: Standard cubic feet per
minute; a unit of measure of air
delivery.
PSIG: Pounds per square inch
gauge; a unit of measure of pressure.
Code Certification: Products that
bear one or more of the following
marks: UL, CUL, ETL, CETL, have
been evaluated by OSHA certified
independent safety laboratories and
meet the applicable Underwriters
Laboratories Standards for Safety.
Cut-In Pressure: While the motor
is off, air tank pressure drops as
you continue to use your accessory.
When the tank pressure drops to a
certain low level the motor will restart
automatically. The low pressure
at which the motor automatically
restarts is called "cut-in" pressure.
Cut-Out Pressure: When an air
compressor is turned on and begins
to run, air pressure in the air tank
begins to build. It builds to a certain
high pressure before the motor
automatically shuts off - protecting
your air tank from pressure higher
than its capacity. The high pressure
at which the motor shuts off is called
"cut-out" pressure.
Branch Circuit: Circuit carrying
electricity from electrical panel to
outlet.
Refer to the selection chart located on the unit to select the tools this unit is
capable of powering.
Air Pressure Regulators
• Oil Fog Lubricators
Air Hose:1/4", 3/8" or 1/2" I.D. in
various lengths
DUTY CYCLE
Air compressors should be operated
on not more than a 50% duty cycle.
This means an air compressor that
pumps air more than 50% of one
hour is considered misuse, because
the air compressor is undersized for
the required air demand. Maximum
compressor pumping time per hour is
30 minutes.