Craftsman 921.153120 Air Compressor User Manual


 
77
Troubleshooting Guide
PROBLEM POSSIBLE CORRECTION
Air leaks at the check valve A defective check valve results in a constant air leak at the pressure relief valve
or at the pressure relief valve. when there is pressure in the tank and the compressor is shut off. Drain the tank,
then remove and clean or replace the check valve.
Air leaks between head and Be sure of proper torque on head bolts. If leak remains, contact a service technician.
cylinder.
Air leak from safety valve. Operate the safety valve manually by pulling on the ring. If the valve continues to
leak when in the closed position, it should be replaced.
Pressure reading on the If there is an excessive amount of pressure drop when the accessory is used,
regulated pressure gauge replace the regulator.
drops when an accessory is
used. NOTE:
Adjust the regulated pressure under flow conditions (while accessory is being used).
It is normal for the gauge to show minimal pressure loss during initial use of the
tool.
Excessive tank pressure. Move the Auto-On/Off lever to the Off position. If the unit doesn’t shut off, unplug it
from the power source and contact a service technician.
Motor will not start. Make sure power cord is plugged in and the switch is on. Inspect for the proper size
fuse in your circuit box. If the fuse was tripped, reset it and restart the unit. If
repeated tripping occurs, replace the check valve or contact a service technician.
Excessive moisture in the Remove the water in the tank by draining after each use. High humidity
discharge air. environments will cause excessive condensation. Utilize water filters on your air
line.
NOTE:
Water condensation is not caused by compressor malfunction. Be sure the
compressor’s air output is greater than your tool’s air consumption rate.
Air leaks from the tank body Never drill into, weld or otherwise modify the air tank or it will weaken. The tank can
or tank welds. rupture or explode. Compressor cannot be repaired. Discontinue use of the air
compressor.
The air compressor should be turned off and unplugged from the power source before any maintenance
is performed as well as the air bled from the tank and the unit allowed time to cool. Personal injuries
could occur from moving parts, electrical sources, compressed air, or hot surfaces.
WARNING