Crestron electronic Residential Lighting Work Light User Manual


 
Residential Lighting Design Guide Appendix A
Doc. 5999F 63
Load Schedule with Panel Terminations
Project: Example Residence Dealer: Crestron
Creator: Crestron D3 Pro v2.3.7
Description:
Date: 11/4/2003 System Number: 1
Area Room
Controlled Ckt
Name
Controlled
Ckt No. Fixture Load Type Dim Emergency
Fixture
Watts
Fixture
Qty
Total
Watts Enclosure Slot Module Output
Main
Floor
Bathroom
1
Downlights 009 Downlights Incandescent yes no 100 1 100 Enclosure 1 2 CLX-
1DIM8
1
Main
Floor
Bathroom
1
Downlights 2 008 Downlights Incandescent yes no 100 2 200 Enclosure 1 2 CLX-
1DIM8
2
Main
Floor
Bathroom
1
Downlights 3 006 Downlights Incandescent yes no 100 2 200 Enclosure 1 2 CLX-
1DIM8
3
Main
Floor
Bathroom
1
Drapes 019 Drapes 3-Wire Motor no no 200 1 200 Enclosure 1 4 CLX-
1MC4
1
Main
Floor
Bathroom
1
Exhaust Fan 007 Exhaust Fan Switched no no 200 1 200 N / A N / A Interface
2
1
Main
Floor
Bathroom
2
Downlights 011 Downlights Incandescent yes no 100 1 100 Enclosure 1 2 CLX-
1DIM8
4
Main
Floor
Bathroom
2
Downlights 2 010 Downlights Incandescent yes no 100 3 300 Enclosure 1 2 CLX-
1DIM8
5
Main
Floor
Bathroom
2
Drapes 021 Drapes 3-Wire Motor no no 200 1 200 Enclosure 1 4 CLX-
1MC4
2
Main
Floor
Bathroom
2
Exhaust Fan 012 Exhaust Fan Switched no no 200 1 200 N / A N / A Interface
4
1
Main
Floor
Bedroom Ceiling Fan 022 Ceiling Fan Ceiling Fan no no 100 1 100 Enclosure 1 6 CLX-
1FAN4
1
Main
Floor
Bedroom Downlights 005 Downlights Incandescent yes no 250 2 500 Enclosure 1 2 CLX-
1DIM8
7
Main
Floor
Bedroom Downlights 2 004 Downlights Incandescent yes no 100 4 400 Enclosure 1 3 CLX-
1DIM4
1
Main
Floor
Bedroom Downlights 3 003 Downlights Incandescent yes no 100 1 100 N / A N / A Interface
6
1
Main
Floor
Bedroom Downlights 4 002 Downlights Incandescent yes no 100 1 100 N / A N / A Interface
5
1
Main
Floor
Bedroom Downlights 5 001 Downlights Incandescent yes no 100 2 200 Enclosure 1 3 CLX-
1DIM4
2
Main
Floor
Bedroom Drapes 018 Drapes 3-Wire Motor no no 200 1 200 Enclosure 1 4 CLX-
1MC4
3
Main
Floor
Bedroom Drapes 2 017 Drapes 3-Wire Motor no no 200 1 200 Enclosure 1 4 CLX-
1MC4
4
Main
Floor
Bedroom Drapes 3 016 Drapes 3-Wire Motor no no 200 1 200 Enclosure 1 5 CLX-
1MC4
1
Main
Floor
Foyer Downlights 013 Downlights Incandescent yes no 100 4 400 Enclosure 1 2 CLX-
1DIM8
6
Main
Floor
Sauna Drapes 020 Drapes 3-Wire Motor no no 200 1 200 Enclosure 1 5 CLX-
1MC4
2
*Calculation of load wattage includes transformer loss.
The following three pages contain the complete application diagrams of this example
system, Circuits and Interfaces, Module Wiring, and PAC2 Connections, divided up to
fit the space available. The complete diagram is available on line at:
http://www.crestron.com/dealer-tech_resources/application_diagrams.asp
.