Description
Dayton Model 3VG79 is a 200,000 Btu/Hr heater. This heater uses Kerosene or #1
fuel oil for combustion and electricity to run the motor. It is primarily intended
for indoor or outdoor temporary heating of buildings under construction,
alteration, or repair. It may be used in agricultural, industrial, and commercial
environments.
®
Form 5S4068
Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described.
Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or
property damage! Retain instructions for future reference.
Unpacking
1. Remove all packing items applied to
heater for shipment.
2. Remove all items from carton.
3. Check items for shipping damage. If
heater is damaged, promptly inform
dealer where you bought heater.
Figure 1 - Model 3VG79
ARL LOGO
G 004
®
Amperage
Model Electrical Input (during normal run)
3VG79 120 Volt/60 Hertz 4.5
ELECTRICAL SPECIFICATIONS
GENERAL SPECIFICATIONS
Output Fuel Tank Capacity Fuel Consumption
Model Rating Btu Fuel (U.S. Gallons) (U.S. Gallons/Hr.) Motor RPM
3VG79 200,000 Kerosene or No. 1 fuel oil 13.5 1.4 3450
Fuel Pump Heater Weight Heater Weight Spark Plug Gap
Model Pressure (PSI) (Pounds - with fuel) (Pounds - without fuel) (Inches)
3VG79 6 77 66 .110