Delta DLKC6580V2-1 Air Compressor User Manual


 
21-ENG D26161
Motor
This motor has a manual thermal
overload protector. If the motor over-
heats for any reason, the overload
protector will shut off the motor. The
motor must be allowed to cool down
before restarting. To restart:
1. Place the On/Auto/Off lever in
the Off position.
2. Allow the motor to cool.
3. Depress the red reset button on
the motor.
Additional Service
Disassembly or service of the air
compressor beyond what is covered
in this manual is not recommended. If
additional service is required, contact
your nearest Authorized Warranty
Service Center.
Reset
Button
4. Place the On/Auto/Off lever in
the On/Auto postion to restart
the motor.
IMPORTANT: If the overload protec-
tor shuts the motor off frequently,
check for a possible voltage problem.
Low voltage can also be suspected
when:
1. The motor does not get up to full
power or speed.
2. Fuses blow out when starting the
motor; lights dim and remain dim
when motor is started and is run-
ning.
STORAGE
Before you store the air compressor,
make sure you do the following:
1. Review the “Maintenance” sec-
tion on the preceding pages and
perform scheduled maintenance
as necessary.
2. Set the On/Auto/Off lever to
“OFF”.
3. Close the globe valve.
4. Remove the air tool or accessory.
5. Open the globe valve and allow
the air to slowly bleed from the
air tank until tank pressure is
approximately 20 psi.
6. Drain water from air tank by
opening drain valve (counter-
clockwise) on bottom of tank.
Water will condense
in the air tank. If not
drained, water will
corrode and weaken the air tank
causing a risk of air tank rupture.
7. After the water has been drained,
close the drain or drain valve.
NOTE: If drain valve is plugged,
release all air pressure. The valve
can then be removed, cleaned, then
reinstalled.
8. Protect the air hose from dam-
age (such as being stepped on
or run over).