DeVillbiss Air Power Company D26675 Air Compressor User Manual


 
12- ENG
D26675
TROUBLESHOOTING
PROBLEM
CAUSE
CORRECTION
Voltage sources, moving parts, or compressed air sources
are exposed when repairing the compressor. Personal
injury can occur. Unplug the compressor before attempting any repairs.
Hose fitting loose. Tighten fitting.Air Leaks
Prolonged excessive use of
air.
Decrease the amount of air
usage. Your compressor is
not large enough for the air
requirement.
Compressor is
not delivering
enough air.
Motor will not
run.
Fuse blown, circuit breaker
tripped.
1.Check fuse box for blown
fuse and replace as
necessary. Reset circuit
breaker. Do not use a fuse
or circuit breaker with
higher rating than that
specified for your
particular branch circuit.
2.Check for proper fuse.
You should be using a
“Time Delay” fuse.
3.Check for low voltage
problem.
4.Check the extension cord.
5.Disconnect the other
electrical appliances from
circuit or operate the
compressor on its own
branch circuit.
Loose electrical
connections.
Check wiring connection
inside terminal box area.
Faulty motor.
High discharge
pressure.
Cannot be
adjusted lower.
Adjustable pressure valve
not functioning.
Risk of
bursting.
DO NOT operate the
compressor if this problem
exists. Adjustable pressure
valve must be replaced.
Hole in hose.
Air leaks.
Replace the hose.
Tighten fittings.
Extension cord is wrong
length or gauge.
Check the extension cord.
Contact a Trained Service
Technician.